WITH CORRECT ANSWERS 2025
Trigger - CORRECT ANSWER -
Serves as the integration point between the application workflow and Bridges
-generally an action in Hyperspace, like clicking a button or closing an activity
-
a single, clearly defined action that a user or process can take that results in an interface message bei
ng created and sent
An interface message contains.... - CORRECT ANSWER -
Data about an event (like a patient being admitted to the hospital)
MSH-11 and MSH-12 are... - CORRECT ANSWER -
the HL7 processing ID and version; Epic checks these values on an incoming message and rejects the
message if they do not match the expected values
Segment Identifier - CORRECT ANSWER -
Three character code that identifies what kind of data that segment contains
PID-5 - CORRECT ANSWER -patient name
NTE segment - CORRECT ANSWER -can follow many different segments
Z-segment - CORRECT ANSWER -custom segment for a specific implementation
Is it necessary to send empty fields following the last valued field? - CORRECT ANSWER -No
Within a field do you need to send all components? - CORRECT ANSWER -Only as many as are valued
,Blank fields... - CORRECT ANSWER -don't file anything
Delete character HL7 - CORRECT ANSWER -double quotes " "---
tells the receiving system to delete a piece of info it has
FHIR - CORRECT ANSWER -specifies RESTful exchange method via HTTPs to access data
Other standards supported by Bridges - CORRECT ANSWER -X12, FHIR, NCPDP, DICOM, and Direct
Event (in context of outgoing message flow) - CORRECT ANSWER -
small set of values with the necessary info to build the message: patient ID, patient contact, type of m
essage, and additional info
-contains directions for where the interface should pull the information it needs from the database
Queue - CORRECT ANSWER -storage location outside of Chronicles database structure
Event Queue is procesed by... - CORRECT ANSWER -the Event Daemon
Daemon (Outgoing Message Flow) - CORRECT ANSWER -
process that runs in the background without any direct user action
Event Daemon (Outgoing Message Flow) - CORRECT ANSWER -
pulls an event off the Event Queue, uses the information in the event to build the message and finally
deletes the event from the event queue.
The event daemon puts the message it has built onto the data queue and adds an instruction to the C
ontrol Queue
builds an HL7 message based on data pulled from Chronicles
, Data Queue (Outgoing Message Flow) - CORRECT ANSWER -
contains the full text of the message along with some additional metadata (i.e. timestamp) about mes
sage processing
Control Queue (Outgoing Message Flow) - CORRECT ANSWER -a to-do list and contains very little data
-processed by the Communications Daemon
-maintains a list of messages waiting to be processed
Comm Deamon (Outgoing Message Flow) - CORRECT ANSWER -
reads an instruction from the Control Queue and copies the appropriate message off the Data Queue
-sends the message out of Epic and waits for an ACK to be reutrned
-deletes instruction from the Control Queue and proceeds to the next instruction
-sends or receives acknowledgments over a TCP/IP connection
Comm Daemon (Incoming Message Flow) - CORRECT ANSWER --
listens constantly for messages coming into the system
-validates MSH-11 and MSH-
12 before accepting it, storing it in the data queue, and adding instruction to the control queue
-sends or receives acknowledgments over a TCP/IP connection
Control Queue (Incoming Message Flow) - CORRECT ANSWER -processed by the Filer Daemon
Filer Daemon - CORRECT ANSWER -
pulls an instruction from the Control Queue, retrieves the corresponding message from the Data Queu
e, and then attempts to file the message.
Filing means that the Filer Daemon attempts to store the data in Chronicles.