NEIEP 800 FINAL EXAMS (LATEST 2025 UPDATES
STUDY BUNDLE WITH COMPLETE SOLUTIONS)
QUESTIONS AND VERIFIED ANSWERS | 100%
CORRECT | GRADE A
Hydro elevators in low rise applications do not need an _____
_____ room. .....ANSWER.....overhead machine
Some advantages of hydros are lower equipment and building
construction costs because the load of a hydro is carried to the
_____ where as the load of a traction car is carried by the
_____ _____. .....ANSWER.....ground, building structure
When drilling the jack hole, the only proper way to determine if
the hole is plumb is to remove the drill stem and bit and use a
_____ _____. .....ANSWER.....Spider Bob
,Page 2 of 162
To plumb the hole, a spider bob is attached to a length of piano
wire suspended from as near as possible to the top of the _____
or from a fixed point on the drill rig. .....ANSWER.....Hoistway
When welding a joint, lay _____ inch tack welds _____ degrees
apart, shift it 90 degrees and lay two more 1 inch tack welds
180 degrees apart. .....ANSWER.....1, 180
On power units having the motor beneath the tank, the pump
may be either _____ driven or _____ coupled.
.....ANSWER.....belt, direct
The purpose of the _____/_____ is to silence the effect of any
pulsations in the pump output and should be as close to the pump
as possible. .....ANSWER.....silencer, muffler
On Bolsters/Bolster Assembly, the plunger is fastened to the
_____ _____ which is then mounted to the center of the Bolster
Assembly. .....ANSWER.....platen plate
,Page 3 of 162
With wye-delta, reduced current starting is accomplished without
the need for _____. .....ANSWER.....resistors
_____ run buttons should run the platform and sling at leveling
speeds only. .....ANSWER.....Temporary
A _____ _____ consists of a piston held closed by an adjustable
spring and must open at a certain pressure to prevent any
further increase in pressure. .....ANSWER.....relief valve
A _____ lowering valve allows the car to be lowered at a speed
not exceeding 20fpm in case of power failure.
.....ANSWER.....manual
As the oil temperature changes, the _____ will change as well
and will effect the performance, more specifically, the leveling
and approach of the elevator. .....ANSWER.....viscosity
Be sure wellways are properly _____ to avoid accidental injury
to you, your team or anyone working outside of our industry.
.....ANSWER.....barricaded
, Page 4 of 162
Barricades around the wellway must be _____ inches high and
be capable of withstanding a _____lb force. .....ANSWER.....42,
200
A _____ protects you if you come in contact with a hot wire or
component and then come in contact with ground. It opens the
circuit and diverts the supplied current to ground.
.....ANSWER.....GFCI
A _____ _____ is useful for horizontal (side-to-side) pulling of
the truss while being lowered into the wellway.
.....ANSWER.....lever hoist
Code specifies the use of anti-slide devices if the outer edge of
the deck is greater than _____ inches from the center line of the
handrail. .....ANSWER.....12
(True/False) Anti-slide devices must be less than 3/4" in height,
have no sharp corners or edges and fastened to the deck no