QUESTIONS WITH CORREC ANSWERS 2025
Family of burrs provides maximum visibility due to the following - CORRECT ANSWER -clearshroud/hood
The power pick instrument was initially designed to do - CORRECT ANSWER -micro fracture procedures
The torpedoes shaver had which of the followingVfeatures - CORRECT ANSWER -A tapered cottical tip
T/F the power rasp attachment is a motion device that creates a smooth flat surface -
CORRECT ANSWER -False
Which shaver oscialtes by its most agressive tissue resection and control - CORRECT ANSWER -
Agg (agressive)
How many hand pieces can be connected and controlled simultaneously by the synergy resection conso
le? -VCORRECT ANSWER -2
What is the largest arthroscopic section for the bipolar RF Products? - CORRECT ANSWER -Shoulder
The bipolar ablation breaks down tissue by the following process? - CORRECT ANSWER -
Chemical reaction
The metal detection feature on the synergy fr bipolar ablation system performs what function? -
CORRECT ANSWER -
Suspends power to the probe when the tip is in close proximity of the scope or metal instruments
When using bipolar RF technology, the clinical guidelines include? - CORRECT ANSWER -All of the above
The default ablation setting levels for the mp90 probe is? - CORRECT ANSWER -7 Ablation
The 3 biproducts of ablation are? - CORRECT ANSWER -Bubbles, Frictional Heat, Light emission
, What are some techniques surgeons use the rf bipolar wands for? - CORRECT ANSWER -All of the above
T/F when removing the orange cap and plugging in the pressure sensor is the first step into your set up
procedure for the dual wave arthroscopy? - CORRECT ANSWER -T
The purpose of the shaver boost mode on the dual wave arthroscopy pump is? - CORRECT ANSWER -
Increase the pressure when shaver is activated
T/F The dual wave arthroscopy pump is designed to opperate as either inflow-
outflow or an inflow only pump? - CORRECT ANSWERV-T
If the dual wave arthroscopy pump height is 1ft above the operative site what is the differential btw the
displayed pressure and actual pressure? - CORRECT ANSWER -22mmhg
The main talking points in introducing the synergy Uhd imaging platform? - CORRECT ANSWER -
All of the above
What type of light engine is in the synergy uhd4 all in 1 camera system? - CORRECT ANSWER -LED
What are the fluid management options the nanoscope operative arthroscopy system? -
CORRECT ANSWER -Syringe, gravity, and pump systems
The target used space for the nanoscope operative arthroscopy system include? - CORRECT ANSWER -
Clinic, Procedure Rooms, ORs
The nanoscope operative arthroscopy system differs from its competitorsVall of the following ways exce
pt? - CORRECT ANSWER -Offering the camera with the smallest diameter
Surgical repair of the lateral ankle ligament of the Atfl is most often accomplished with what procedure
? - CORRECT ANSWER -The modified brostrum gold procedure