Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 3 out of 18 pages
Exam (elaborations)

Wastewater Class B Texas questions with correct answers Graded A+ Updated Version

Document preview thumbnail
Preview 3 out of 18 pages

Wastewater Class B Texas questions with correct answers Graded A+ Updated Version

Content preview

Wastewater Class B Texas questions
with correct answers | Graded A+ |
Updated Version
QUESTIONS AND ANSWERS
The name of the State Agency responsible for enforcing pollution control laws in
Texas. ANSWER -Texas Commission of Environmental Quality


The term pathogenic means. ANSWER -Capable of causing disease


The minimum separation between sewer lines and potable water lines is. ANSWER -
9 feet


A licensed wastewater operator is a professional. ANSWER -consistently does best
job possible, practices personal safety, strives to improve job knowledge, strives to
keep the plant and collection system in the best appearance and working order


An important step in testing a sample for Total Suspended Solids is. ANSWER -
Filtering a sample


The Biochemical oxygen Demand (BOD) of a sample is based on. ANSWER -
Measuring the dissolved oxygen (DO) used


The results of Biochemical Oxygen Demand (BOD) sample taken at a treatment
plant tells the operator. ANSWER -How the plant was operating 5 days ago


Which of the following are dangerous gasses that are likely to be present in lift
stations and manholes?. ANSWER -Natural gas, gasoline fumes, hydrogen sulfide
and carbon dioxide


A preferred hydraulic method of cleaning sewer lines is. ANSWER -Hydro Jet
Cleaner

,Ways to reduce bad odors coming from a collection system. ANSWER -routinely
cleaning slow running or low flow lines, adding chlorine or hydrogen peroxide to the
collection system


Types of pipe that are commonly used in wastewater collection system. ANSWER -
ductile iron, Poly Vinyl Chloride (PVC)


Before entering a confined space a worker should. ANSWER -Use approved
monitoring device and check for the presence of dangerous gasses, ventilate the
space with a blower, wear a safety harness and attach a life line


A properly designed and operated primary sedimentation tank should remove _____
percent of incoming BOD. ANSWER -30-40%


Devices that may be used to determine the level of sewage in a lift station. ANSWER
-air bubbler, floats, electrodes, Acoustic (sonic)


What is the most important role of aerobic bacteria in the treatment of wastewater?.
ANSWER -decompose organic matter


The hydraulic loading of a trickling filter may be determined by. ANSWER -flow
rate and filter area


These can be used to dewater sludge. ANSWER -belt press, drying beds, solid bowl
centrifuge, gravity thickener


Most important to providing adequate sewage treatment in a stabilization pond.
ANSWER -sunlight, algae, bacteria and time


Offensive and objectionable odors which sometimes occur in trickling filters usually
indicate. ANSWER -septic conditions are present


Dissolved Oxygen (DO) in aeration tank of an activated sludge plant should be
maintained at or about. ANSWER -2 to 4 mg/L

, Contributes to the infiltration in a collection system. ANSWER -breaks in the main
lines, high ground water levels, heavy rains, hydro jet cleaning plugged mains


When a centrifuge pump loses prime the. ANSWER -pump is no longer moving
liquid


A Rotating Biological Contactor (RBC) is. ANSWER -fixed firm biological treatment
process


Needs to be checked regularly to properly operate an activated sludge treatment
plant. ANSWER -aeration equipment and mixed liquor solids


Point source discharges are. ANSWER -discharges that come from pipes or ditches
that are monitored, controlled and inspected


Non-point discharges are. ANSWER -discharges that have intermittent, dispersed
flows having little or no control


The Texas Water Code establishes the protection of water quality and quantity of
the state by. ANSWER -setting stream standards, issues permits for discharges,
identifies non-point source controls, and establishes water reuse.


The wastewater plant operator is primarily responsible for. ANSWER -treating
wastewater discharged into the community


Chapter ___ of the Texas Water Code is the state law controlling water pollution
and ___ authority to control discharges in Texas. ANSWER -Chapter 26 and Texas
Commission of Environmental Quality


The Texas Commission on Environmental Quality can revoke an operator's license if
the operator. ANSWER -causes permit violation, falsifies records or neglects their
duty


If accidental discharge, bypass, or spill (SSO) of wastewater occurs the responsible
party MUST notify TCEQ regional offices within ____ hours. ANSWER -24

Document information

Uploaded on
November 18, 2025
Number of pages
18
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$12.39

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
8
Followers
0
Items
1088
Last sold
1 month ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions