100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

AWWA Backflow Prevention Assembly Testing: Key Procedures and Troubleshooting Exam 2026 Questions and Answers

Rating
-
Sold
-
Pages
25
Grade
A+
Uploaded on
10-11-2025
Written in
2025/2026

AWWA Backflow Prevention Assembly Testing: Key Procedures and Troubleshooting Exam 2026 Questions and Answers

Institution
Virginia Commercial Pesticide Applicators CORE
Course
Virginia Commercial Pesticide Applicators CORE










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Virginia Commercial Pesticide Applicators CORE
Course
Virginia Commercial Pesticide Applicators CORE

Document information

Uploaded on
November 10, 2025
Number of pages
25
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

AWWA Backflow Prevention Assembly
Testing: Key Procedures and
Troubleshooting Exam 2026 Questions
and Answers

When testing a reduced pressure principle backflow prevention assembly, there is

intermittent spitting from the relief valve. What is the possible cause of the

spitting? - Correct answer-supply pressure fluctuations

When testing the air inlet of a pressure vacuum breaker the hose(s) on the test kit

shall be connected in this manner: - Correct answer-High side hose to the #2

testcock

When testing the #1 check valve of a double check valve assembly you have

opened the #3 testcock to the atmosphere. The water recedes from the sight tube.

How do you proceed? - Correct answer-Lower the test kit to the centerline of the

assembly; record the reading as the static pressure drop across the #1 check valve.

Note that the #2 check valve and the #2 shut off valve are leaking and terminate the

test.

©COPYRIGHT 2025, ALL RIGHTS RESERVED 1

,As you move water from the high side of the #1 check valve to the low side of the

#2 check valve of a reduced pressure principle backflow prevention assembly, the

indicator on the test kit falls to the low end of the scale and the differential pressure

relief valve discharges a continuous stream of water. How do you proceed? -

Correct answer-Open the low side bleed needle valve to re-establish differential

pressure above the apparent differential pressure to give the #2 check a second

chance.

When testing a double check valve assembly and the #1 check valve fails you may

proceed in the following manner: - Correct answer-Fail the #1 check valve and

continue to test the #2 check valve

The correct procedure to test the #1 check valve of a double check valve assembly

is to: - Correct answer-Install the bleed arrangement on the #2 testcock before

purging air from the test kit

As you start to test the air inlet on a pressure vacuum breaker you close the #2 shut

off valve, raise your test kit to the appropriate elevation and close the #1 shut off

valve. You open the high side bleed needle valve one quarter turn. Water continues

to discharge from the high side bleed needle valve and the indicator on your test kit

remains at the high side of the scale. How do you proceed? - Correct answer-Open

the #1 testcock to compensate for a leaking #1 shut off valve.

©COPYRIGHT 2025, ALL RIGHTS RESERVED 2

, Regarding question #4, after you have opened the low side bleed needle valve and

re-established the differential pressure above the apparent differential pressure, you

close the low side bleed needle valve. Now you test kit indicates an acceptable

value for the actual differential pressure across the #1 check valve. How do you

proceed? - Correct answer-Accept the value as the actual differential pressure

across the #1 check valve

When testing the #2 check valve of a double check valve assembly you open the #4

testcock. Water continues to discharge from the sight tube and the bleed valve

arrangement, after you have opened the bleed valve arrangement completely on the

#3 testcock. How do you proceed? - Correct answer-Close the bleed valve

arrangement and open the #2 testcock to compensate for a leaking #1 shut off valve

When testing the #2 check valve of a double check valve assembly you open the #4

testcock. The water in the sight tube recedes. How do you proceed? - Correct

answer-Lower the test kit to the centerline of the assembly and record the reading

on the test kit noting the #2 shut off valve is leaking with demand.

When testing the #1 check valve of a double check valve assembly it is necessary

to use the bleed valve arrangement to compensate for a leaking #1 shut off valve.

The static pressure drop across the #1 check valve as indicated by the test kit is 0.6




©COPYRIGHT 2025, ALL RIGHTS RESERVED 3

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
EmillyCharlotte Howard Community College
View profile
Follow You need to be logged in order to follow users or courses
Sold
98
Member since
1 year
Number of followers
5
Documents
12005
Last sold
3 weeks ago
ALL-MAJOR.

On this page, you find all documents, package deals, and flashcards offered by seller Emilly Charlotte.

3.5

21 reviews

5
7
4
6
3
2
2
3
1
3

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions