NM ES-3 TEST QUESTIONS AND ANSWERS

What is the minimum clearance to the edge of a wood stud for a wire hole? - Answer -1
1/4 inches(NEC 300.4 A 1)

What is the minimum separation between a class 1 fire alarm circuit conductor and a
class 2 or class 3 circuit? - Answer -1/4 inch

A basic alarm system will have __ power sources. - Answer -2

What is the minimum required clearance between a receiving antenna and 250 volt line
not insulated? - Answer -2 Feet

The minimum clearance for an antenna to other conductors is? - Answer -2 Feet (NEC
810.13)

How far away must communications cables be from electric, light, or power conductors -
Answer -2 inches

what is the maximum blink rate on a strobe light per second? - Answer -2 (NFPA 72
18.5.2.1)

On a voice alarm system what is the minimum number of cycles it has to report an
evacuation procedure? - Answer -2 (NFPA 72 24.4.1.2.1)

What is the minimum required height for a propriety manual pull fire alarm? - Answer -3
1/2 feet or 42 inches

An overhead feeder must have a clearance of __ from chimneys, radio, and television
antennas. - Answer -3 Feet (NEC 225.19 B)

The NEC classifies Continuous Load as equipment running at a maximum load of __
____? - Answer -3 hours

A continuous load is a load where the maximum current is expected to continue for a
certain length of time. This amount of time is? - Answer -3 hours or more

The minimum head room of working space above service equipment, switchboards,
panel boards, or motor control centers shall be at least: - Answer -6.5 feet

What is the minimum required separation between communication cables and lighting
conductors? - Answer -6 feet

What is the minimum separation required between coaxial cable in a CATV system and
lighting conductors - Answer -6 feet

, On a radio antenna receiving station what is the minimum clearance between lead-in
conductors and conductors forming a part of a lightning protection system? - Answer -6
feet

What is the minimum length of a grounding rod in an application of less than 50 volts? -
Answer -8 Feet (NEC 250.5.2.5)

Utility owned low-voltage communication, radio, and television coaxial cables may pass
directly over a pool if at a minimum height of: - Answer -10 feet

All of the following is acceptable as a ground except? - Answer -10 foot gas pipe (NEC
250.5.2 A)

An antenna is installed on a building for signal reception, what is the smallest size
copper grounding conductor that would be permitted? - Answer -10 Gauge (NEC
810.21.8 H)

Electrical conduit buried 18 inches below grade shall have a warning tape at how many
inches above the conduit? - Answer -12 inches (NEC 300.5 D 3)

What is the smallest ground wire to to communications box - Answer -14 AWG (NEC
830.100 A 3)

What is the minimum size grounding conductor for communications circuits - Answer -
14 AWG

What is the maximum interval the fire alarm signal is allowed at the consul? - Answer -
15 Seconds (NFPA 72 23.8.1.3.1.1)

What is the minimum wire size for connecting bells, sirens, or control circuitry? -
Answer -18 AWG (NEC 760.49 A)

According to NEC class 3 circuits are allowed a minimum wire size of what gauge? -
Answer -18 AWG (NEC 725.179 H)

What is the maximum number of supervisory switches permitted to be connected to a
actuate a single transmitter? - Answer -20

Type PLTC nonmetallic sheathed shall be a minimum size ___ gauge for class 3 circuits
and have an insulation rating of atleast 300 V - Answer -22 (NEC 725.179 E)

A rotary phase converter has a nameplate rating of 28 full load input amps, disregard
the exceptions, what is the minimum ampacity required for the conductor supplying the
phase converter? - Answer -"35 (NEC 455.6 A1)

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
GEEKA YALA UNIVERSITY
View profile
Follow You need to be logged in order to follow users or courses
Sold
2009
Member since
3 year
Number of followers
1447
Documents
48320
Last sold
1 day ago

3.8

345 reviews

5
172
4
61
3
44
2
16
1
52

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions