spacing for smoke detectors or manufactured specs - ANSWERrule of thumb - 30ft manual pull station height - ANSWER3-1/2 to 4-1/2 ft secondary power must turn of within ? seconds on loss of primary supply - ANSWER10 seconds manual pull stations must be mounted

Show more Read less
Institution
OHIO FIRE ALARM
Course
OHIO FIRE ALARM








Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
OHIO FIRE ALARM
Course
OHIO FIRE ALARM

Document information

Uploaded on
November 3, 2025
Number of pages
3
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

STATE OF OHIO FIRE ALARM TEST -
STUDY GUIDE CORRECT 100%
spacing for smoke detectors or manufactured specs - ANSWERrule of thumb - 30ft

manual pull station height - ANSWER3-1/2 to 4-1/2 ft

secondary power must turn of within ? seconds on loss of primary supply - ANSWER10
seconds

manual pull stations must be mounted within ? feet of exits on each floor and spaced up
to ? - ANSWER5 ft, 200 ft

residential, secondary power supply time - ANSWER24 hours in normal, 4 minutes of
full alarm

commercial, secondary power supply time - ANSWER24 hours in normal, 5 minutes of
full alarm

live voice, secondary power supply time - ANSWER24 hours in normal, 15 minutes of
full power

trouble signals must be restored in ? seconds - ANSWER200 seconds

door header wall space of ? inches or more requires a one detector on either side of the
door - ANSWER24 inches

what can be used to activate (test) smoke detectors - ANSWERapproved aerosols,
canned smoke

coded alarm systems must repeat the code signal at least ? times - ANSWER3

smoke detectors can be mounted, ? ,in relation to a duct - ANSWERIn a duct, on a duct,
or project through a duct

smoke detectors, CAN or CANNOT, be recessed in wall - ANSWERcannot UNLESS
listed for such mounting

visual appliances are mounted not less than ? inches or no greater than ? inches -
ANSWER80 inches, 96 inches (for ceilings less than 86 inches, visual lens mounting
height shall be WITHIN 6 inches of the ceiling)

audible devices are mounted above the floor no less than ? inches and below the ceiling
? inches - ANSWER90 inches, 6 inches

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
shantelleG West Virgina University
View profile
Follow You need to be logged in order to follow users or courses
Sold
614
Member since
2 year
Number of followers
369
Documents
17946
Last sold
4 days ago
GOLD PREMIUM

HELLO? welcome to my store thanks for visiting this page here you are guaranteed of well revised and assured EXAMS ALL GRADED A+ thus making your education journey easy and seamless . DO NOT HESITATE TO CONTACT ME IF YOU ARE IN NEED OF ANY EXAM .I AM READY 24/7 TO ASSIST YOU ALSO REFER YOUR FRIENDS.

4.1

115 reviews

5
69
4
10
3
22
2
2
1
12

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can immediately select a different document that better matches what you need.

Pay how you prefer, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card or EFT and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions