100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

Journeyman Oil Maine Fuel Board Rules Exam fully solved & updated (latest version verified for accuracy) | Latest!!

Beoordeling
-
Verkocht
-
Pagina's
22
Cijfer
A+
Geüpload op
11-10-2025
Geschreven in
2025/2026

Journeyman Oil Maine Fuel Board Rules Exam fully solved & updated (latest version verified for accuracy) | Latest!!

Instelling
Journeyman Oil Maine Fuel Board Rules
Vak
Journeyman Oil Maine Fuel Board Rules










Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Journeyman Oil Maine Fuel Board Rules
Vak
Journeyman Oil Maine Fuel Board Rules

Documentinformatie

Geüpload op
11 oktober 2025
Aantal pagina's
22
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

Journeyman Oil Maine Fuel Board Rules Exam fully solved & updated
2025-2026(latest version verified for accuracy) | 2024\2025Latest!!

1. What must you do if you notice code violations in a Notify them and recom-
homeowners house? mend ways to address
them

2. What must be done when performing an annual A combustion efficiency
tune-up on a heating system? test and a copy must be
posted on site

3. Whenever a furnace, direct fired hot water heater, NFPA 31
or boiler is installed the total installation must be
brought into compliance with what requirements BE-
FORE appliance can be fired?

4. When an emergency arises that does not allow ade- 90 days
quate time to get a chimney lined/and or repaired be-
fore installing the new heating appliance the licensee
may defer the required repairs for how long?

5. What must be performed before a new installation? A heat loss system de-
sign and load calculation.
A copy must be retained
to be presented upon re-
quest of board inspector

6. All oil fired BOILERS must be provided with a properly Low Water cut off
installed and operating what?

7. Where shall a low water cutoff be installed? At the level recommended
by the manufacture, but in
no case below the crown
sheet




, Journeyman Oil Maine Fuel Board Rules Exam fully solved & updated
2025-2026(latest version verified for accuracy) | 2024\2025Latest!!

8. If the low water cut off is not installed directly in the Main supply line (vertical
boiler where may it be installed? riser) as close to boiler as
possible, or in a water col-
umn of continuous pip-
ing attached directly to the
boiler

9. A listed lever or wheel thermally operated oil shut off At the burner and the oil
valve must be installed where? supply tank

10. When outside tanks are used a thermally operated The supply line enters the
shut off valve must be installed where? inside of the building and
where the oil line enters
the room where the appli-
ance is located

11. When inside tanks are used and the oil supply tank is Where the line enters the
installed in a separate room, a thermally shutoff valve room where the appliance
must be installed where? is located

12. Whenever the oil supply is taken from the top of an oil At the tank and at the
tank a thermally operated wheel or lever type shut-off burner
valve must be installed where?

13. What may be installed in the supply line but not a A check valve
return line?

14. All copper oil supply and return lines must be en- 2 inches
cased in a continuous piece of no metallic liquid tight
conduit such as PVC, ENT, coated copper tubing. The
end of the conduit shall not exceed how far from any
connection except the connection at fuel tank?



, Journeyman Oil Maine Fuel Board Rules Exam fully solved & updated
2025-2026(latest version verified for accuracy) | 2024\2025Latest!!

15. In order to avoid undetected oil leaks under floors, One pipe size larger
the conduit must be how much bigger than the supply
and return lines?

16. An oil supply line that penetrates a foundation wall Sealed
must be what?

17. What must coated copper tubing have installed at the Oils Safety Valve or PRV
tank when used underground?

18. When an oil filter or other accessory equipment is Rigidly supported by wall
connected to a copper piping smaller than 3/4 "and or floor mounted brackets
is not directly connected to the oil tank or burner the
filter or other device must be what?

19. What must supply and return lines be connected with? Flare fittings

20. What fittings shall not be used unless for introduction Compression fittings
of lines at top of the tank with a single or double tap
bushing?

21. All connections of supply or return oil lines located Flare frost fittings
outside must be made with what?

22. Manholes 16 inches in diameter or larger must be 5,000 gallons or more
installed in the top of all tanks over what?

23. All fuel oil supply tanks must be a minimum of how 5 feet
many feet from any gas or solid fuel burning appli-
ance?

24. Outside oil tanks shall not be installed on what? Wood or other com-
bustible surfaces

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
CodedNurse Nightingale College
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
3796
Lid sinds
1 jaar
Aantal volgers
20
Documenten
8755
Laatst verkocht
9 uur geleden
coded

"I specialize in key academic areas such as Psychology, Nursing, Human Resource Management, and Mathematics. Providing students with top-quality work is my priority, and I always uphold the highest scholarly standards. This commitment has earned me the distinction of being a Gold-Rated Tutor on Stuvia. You can trust my work to help you achieve excellent grades!"

3.4

65 beoordelingen

5
18
4
16
3
15
2
3
1
13

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen