FDNYC G60 Practice Exam Question &
Answers ( Latest update)
All torch operators, an oxigen-fuel torch using any amount of oxigen
and flamable gas and fire guards must have a current - CORRECT
ANSWERS ✔✔Certificate of Fitness
The Certificate of Fitness holder - CORRECT ANSWERS ✔✔must
regulate the pressure and flow of oxygen and natural gas to each torch.
if the torch operator for jewelry manufacture involves - CORRECT
ANSWERS ✔✔any oxygen with any fuel gas containers, the operator
must be a C of F holder.
A Certificate of Fitness Holder must keep his or her certificate -
CORRECT ANSWERS ✔✔on their person or otherwise readily
available for inspection by any representative of the fire Department
The easiest way to extinguish a fire caused by a leak is to - CORRECT
ANSWERS ✔✔close the shutoff valve
Permits issued by the FDNY are required to conduct the following hot
work: - CORRECT ANSWERS ✔✔storing, using or handling oxygen
and a flammable gas, storing, using or handling any flammable gas (e.g.
LPG or CNG or acetylene) in excess of
400 SCF. Storing, using or handling any oxidizing gas (e.g. oxygen) in
excess of 504 SCF.
,FDNYC G60 Practice Exam Question &
Answers ( Latest update)
For LPG, 400 SCF is - CORRECT ANSWERS ✔✔approximately 47 lbs
the number of LPG containers for the storage, use, handling or
transportation, requiring a permit - CORRECT ANSWERS ✔✔14.1 oz
= 54 cont.
16.4 oz = 46 cont.
20 lbs = 3 cont.
33.5 lbs = 2 cont.
40 lbs = 2 cont.
100 lbs = 1 cont.
Portable LPG containers that are more than 16.4 oz and CNG containers
with a capacity greater than 8.7 SCF - CORRECT ANSWERS ✔✔must
NOT stored, handled, or used indoors in the following occupancies (as
defined in the Building code): residential occupancies, factory and
industrial occupancies; educational occupancies; institutional
occupancies, except as the commissioner may authorize by rule.
Site-specific permit - CORRECT ANSWERS ✔✔may be a permanent
permit or a temporary permit. Permanent permits are valid for 12
months only
, FDNYC G60 Practice Exam Question &
Answers ( Latest update)
A city-wide permit is valid - CORRECT ANSWERS ✔✔up to 30 days
Permits shall be - CORRECT ANSWERS ✔✔readily available on the
premise for inspection by Fire Department representatives.
Hot work authorization should be issued by the responsible person, and
it - CORRECT ANSWERS ✔✔must be available for inspection by any
representative of the department during the performance of the work,
and for 48 hours after the work is complete
FDNY permits - CORRECT ANSWERS ✔✔will be posted in a central
location and recorded in a log book to assist in the coordination of
construction related activities.
CNG - CORRECT ANSWERS ✔✔Compressed Natural Gas.
For Citywide hot work operations, the Owner of the premises must be
notified in writing at least _____ hours in advance prior to work
beginning. - CORRECT ANSWERS ✔✔48
A class A fire extinguisher fights fires from - CORRECT ANSWERS
✔✔Paper
Answers ( Latest update)
All torch operators, an oxigen-fuel torch using any amount of oxigen
and flamable gas and fire guards must have a current - CORRECT
ANSWERS ✔✔Certificate of Fitness
The Certificate of Fitness holder - CORRECT ANSWERS ✔✔must
regulate the pressure and flow of oxygen and natural gas to each torch.
if the torch operator for jewelry manufacture involves - CORRECT
ANSWERS ✔✔any oxygen with any fuel gas containers, the operator
must be a C of F holder.
A Certificate of Fitness Holder must keep his or her certificate -
CORRECT ANSWERS ✔✔on their person or otherwise readily
available for inspection by any representative of the fire Department
The easiest way to extinguish a fire caused by a leak is to - CORRECT
ANSWERS ✔✔close the shutoff valve
Permits issued by the FDNY are required to conduct the following hot
work: - CORRECT ANSWERS ✔✔storing, using or handling oxygen
and a flammable gas, storing, using or handling any flammable gas (e.g.
LPG or CNG or acetylene) in excess of
400 SCF. Storing, using or handling any oxidizing gas (e.g. oxygen) in
excess of 504 SCF.
,FDNYC G60 Practice Exam Question &
Answers ( Latest update)
For LPG, 400 SCF is - CORRECT ANSWERS ✔✔approximately 47 lbs
the number of LPG containers for the storage, use, handling or
transportation, requiring a permit - CORRECT ANSWERS ✔✔14.1 oz
= 54 cont.
16.4 oz = 46 cont.
20 lbs = 3 cont.
33.5 lbs = 2 cont.
40 lbs = 2 cont.
100 lbs = 1 cont.
Portable LPG containers that are more than 16.4 oz and CNG containers
with a capacity greater than 8.7 SCF - CORRECT ANSWERS ✔✔must
NOT stored, handled, or used indoors in the following occupancies (as
defined in the Building code): residential occupancies, factory and
industrial occupancies; educational occupancies; institutional
occupancies, except as the commissioner may authorize by rule.
Site-specific permit - CORRECT ANSWERS ✔✔may be a permanent
permit or a temporary permit. Permanent permits are valid for 12
months only
, FDNYC G60 Practice Exam Question &
Answers ( Latest update)
A city-wide permit is valid - CORRECT ANSWERS ✔✔up to 30 days
Permits shall be - CORRECT ANSWERS ✔✔readily available on the
premise for inspection by Fire Department representatives.
Hot work authorization should be issued by the responsible person, and
it - CORRECT ANSWERS ✔✔must be available for inspection by any
representative of the department during the performance of the work,
and for 48 hours after the work is complete
FDNY permits - CORRECT ANSWERS ✔✔will be posted in a central
location and recorded in a log book to assist in the coordination of
construction related activities.
CNG - CORRECT ANSWERS ✔✔Compressed Natural Gas.
For Citywide hot work operations, the Owner of the premises must be
notified in writing at least _____ hours in advance prior to work
beginning. - CORRECT ANSWERS ✔✔48
A class A fire extinguisher fights fires from - CORRECT ANSWERS
✔✔Paper