CORRECT Answers GRADED A+ GUARANTEED 100% PASS
3.3.8 What is an Addressable Device? - (answer)It is a fire alarm system component that possesses
discreet identification.
__________ Detector has a piping distribution network to the areas being protected. Air Sampling-Type
detector uses a fan inside its housing to draw air. - (answer)3.3.66.1 Air sampling-type
An _________
that transmits a signal indicating varying degrees of condition - (answer)3.3.132.1 Analog Initiating
Device
A __________ can transmit a signal that indicates on off condition only. - (answer)3.3.132.1
Conventional Initiating Device
__________ is a feature that can reduce unwanted alarms. - (answer)3.3.16 Alarm verification
Fire alarms from an auxiliary system are always received at: - (answer)Fire alarms from an auxiliary
system are always received at the public fire service communication center.
Auxiliary Fire Alarm System is connected to: - (answer)Auxiliary Fire Alarm System is connected to a
municipal fire alarm system.
Municipal fire alarm system - (answer)A public emergency alarm reporting system
Auxiliary Fire Alarm System - (answer)A protected premises fire alarm system or other emergency
system at the protected premises and the system used to connected the protected premises system to a
public emergency alarm reporting system for transmitting an alarm to the communications center.
You need to request NFPA to certify your installations. True? - (answer)Not true. The NFPA does not
certify any installations. AHJ is responsible for approving installations.
, NICET - Fire Alarm Systems (Level 2) UPDATED ACTUAL Exam WITH Questions and
CORRECT Answers GRADED A+ GUARANTEED 100% PASS
An AHJ is responsible for: - (answer)An Authority Having Jurisdiction is responsible for approving an
installation.
What is an Annunciator? - (answer)An Annunciator has multiple indicator lamps, alphanumeric
displays... etc... to show status information of a circuits condition.
A __________ Fire Alarm Box requires that you break a special element so to gain access to and operate
the box. - (answer)A Breakglass Fire Alarm Box requires that you break a special element so to gain
access to and operate the box.
What does Compatibility Listed mean? - (answer)Compatibility Listed is a specific listing process that
applies to TWO WIRE DEVICES only.
Combination Detector - (answer)Combination Detector can respond to multiple fire phenomenon.
Equipment is LISTED - (answer)The equipment is included in a list publish by an organization which is
acceptable to the "AHJ"
With a "non-restorable" initiating device: - (answer)the sensing element will be DESTROYED during the
process of operation
What is a pull station? - (answer)PULL STATION is a manually operated device which may be used to
initiate an alarm signal.
Describe NRTL: - (answer)It is the Nationally Recognized Testing Laboratory that is recognized by the
OSHA as meeting the qualifications specified in the Code of Federal Regulations.
CODE - (answer)Code are written rules that are adopted as law.