100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

FLORIDA (FL) SEPTIC TANK CONTRACTOR EXAM | 2 CURRENTLY TESTING EXAM VERSIONS WITH ACCURATE REAL EXAM QUESTIONS AND ANSWERS WITH RATIONALES | EXPERT VERIFIED FOR GUARANTEED PASS | LATEST UPDATE

Puntuación
-
Vendido
-
Páginas
77
Grado
A+
Subido en
26-09-2025
Escrito en
2025/2026

FLORIDA (FL) SEPTIC TANK CONTRACTOR EXAM | 2 CURRENTLY TESTING EXAM VERSIONS WITH ACCURATE REAL EXAM QUESTIONS AND ANSWERS WITH RATIONALES | EXPERT VERIFIED FOR GUARANTEED PASS | LATEST UPDATE

Institución
FLORIDA SEPTIC TANK CONTRACTOR
Grado
FLORIDA SEPTIC TANK CONTRACTOR

Vista previa del contenido

FLORIDA (FL) SEPTIC TANK CONTRACTOR EXAM | 2
CURRENTLY TESTING EXAM VERSIONS WITH ACCURATE
REAL EXAM QUESTIONS AND ANSWERS WITH
RATIONALES | EXPERT VERIFIED FOR GUARANTEED PASS |
LATEST UPDATE




1

The minimum horizontal distance between a septic tank and a private well in Florida is:
A. 50 ft
B. 75 ft
C. 100 ft
D. 125 ft
Answer: B
Rationale: Florida Department of Health (DOH) rules (64E-6 F.A.C.) require a 75-ft separation
to protect groundwater from contamination.



2

Which soil characteristic most strongly affects the absorption capacity of a drainfield?
A. Color
B. Permeability
C. Bulk density
D. Organic content
Answer: B
Rationale: Permeability controls how quickly effluent percolates; it dictates trench size and
system design.



3

,If a proposed drainfield site has a seasonal high water table 18 in. below grade, the minimum
required fill above natural grade is:
A. None
B. 6 in.
C. 24 in.
D. 36 in.
Answer: C
Rationale: Florida code requires at least 24 in. of separation between the bottom of the
drainfield and the seasonal high water table.



4

Which septic system component provides primary treatment by settling solids?
A. Drainfield
B. Effluent filter
C. Septic tank
D. Distribution box
Answer: C
Rationale: The septic tank allows solids to settle and scum to float, providing primary treatment
before effluent reaches the drainfield.



5

When dosing a mound system, the pump chamber must include:
A. Two discharge pumps
B. High-water alarm
C. Chlorine tablet dispenser
D. UV light
Answer: B
Rationale: A high-water alarm alerts to pump or power failures, preventing overflow or backup.

,6

The recommended minimum slope of a gravity building sewer (under 4 in. diameter) is:
A. 1/16 in. per ft
B. 1/8 in. per ft
C. 1/4 in. per ft
D. 1/2 in. per ft
Answer: C
Rationale: Uniform 1/4 in. per foot slope ensures self-cleansing velocity without scouring.



7

What is the maximum design flow for a residential system based on three bedrooms under
Florida code?
A. 250 gpd
B. 300 gpd
C. 450 gpd
D. 600 gpd
Answer: C
Rationale: Florida design flow is 150 gpd per bedroom; three bedrooms × 150 = 450 gpd.



8

Which test determines seasonal high water table when no mottling is observed?
A. Sieve analysis
B. Percolation test
C. Soil borings with piezometers
D. Double-ring infiltrometer
Answer: C

, Rationale: Monitoring wells (piezometers) reveal water table fluctuations where mottling is
absent.



9

The preferred material for modern septic tanks in Florida is:
A. Steel
B. Reinforced concrete
C. Brick
D. Aluminum
Answer: B
Rationale: Reinforced concrete resists corrosion and meets structural requirements; steel is
prone to rust.



10

Before backfilling around a newly installed septic tank, the contractor must:
A. Add chlorine
B. Fill the tank with water
C. Install landscaping
D. Vent the tank
Answer: B
Rationale: Filling prevents flotation or wall collapse during backfill.



11

A pump tank must have a minimum liquid capacity equal to:
A. 50 % of daily flow
B. 100 % of daily flow
C. 150 % of daily flow
D. Twice the daily flow

Escuela, estudio y materia

Institución
FLORIDA SEPTIC TANK CONTRACTOR
Grado
FLORIDA SEPTIC TANK CONTRACTOR

Información del documento

Subido en
26 de septiembre de 2025
Número de páginas
77
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$23.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
DrMedinaReed Chamberlain College Nursing
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
2359
Miembro desde
3 año
Número de seguidores
1319
Documentos
2079
Última venta
15 horas hace
Perfect Expert scores

Welcome to my all inclusive store. Get all quality study materials at a cost-effective price

4.8

2744 reseñas

5
2557
4
64
3
52
2
25
1
46

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes