F-60 FIRE GUARD PRACTICE EXAM QUESTIONS WITH CORRECT DETAILED ANSWERS | ALREADY GRADED A+&lt;RECENT VERSION&gt; 1. The cof holder must keep the cof ___________ or readily available for inspection - answer upon his or her person 2. Portable lpg containers that are more than ________ must not be stored, handled, or used indoors. - answer 16.4 oz 3. Permits shall be readily available on the _________ for inspection by fire department representatives. - answer premises 4. Hot work permits shall be available for inspection by any representative for __________ after the work is complete. - answer 48 hours 5. For _____________, the owner of the hot work operation areas must be notified in writing by the citywide permit holder at least 48 hours before hot work is to be started. - answer citywide hot work operations 6. Pre-hot work checks must be conducted before hot work is authorized and at least ___________. - answer once per day 7. Fire watch will be provided for a minimum of _________ after work is complete. - answer 30 minutes 8. Hot work areas must be kept ___________ feet away from any combustible material. - answer 35 9. Paper, wood shavings, straw and fabric are examples of ______________. - answer combustible material 10. The entire work area should be checked after completion of hot work for __________. - answer fires 11. A minimum ____________ rating fire extinguisher must be readily accessible. - answer 2-a:20-b:c 12. The fire extinguisher must be accessible within __________ feet of hot work location and fire guard. - answer 30 13. For torch-applied roof systems, a minimum ___________ rating fire extinguisher must be readily accessible. - answer 3-a: 40-b:c 14. ___________ protection systems shall not be shut off while hot work is performed. - answer automatic sprinkler 15. Compressed gas containers must be replaced when ___________. - answer they are empty 16. Empty containers must be handled in the same manner as ____________. - answer full ones 17. A ___________ must not be rolled on its side or its rim. - answer compressed gas container 18. The top of the fire extinguisher must not be more than ________ feet above the floor, nor the bottom of the fire extinguisher be less than _________ inches from the ground. - answer 5, 4 19. The cof holder should only consider extinguishing fires when they are ____________. - answer limited in size 20. Never approach a fire from a __________. - answer downwind direction 21. Do not direct the chemical stream at the ________. - answer center of the flame 22. For ________, the gas supply must be shut off first and then call 911. - answer piped gas 23. When not possible to shut off gas supply, allow the flame to ___________ and call 911. - answer burn itself out 24. Class a extinguishers are for extinguishing ___________. - answer ordinary combustibles 25. Class b extinguishers are for extinguishing ___________. - answer flammable or combustible liquids 26. The certificate of fitness holder must keep the certificates of fitness upon his or her person, or otherwise __________________ for inspection by any representative of the department, at all times while conducting or supervising the material, operation or facility for which the certificate is required. - answer readily available 27. Permits issued by the fdny are required to conduct the following hot work: - answer 1)storing, using or handling oxygen and a flammable gas 2) lpg or cng or acetylene in excess of 400 scf 3) any oxidizing gas in excess of 504 scf 28. Portable lpg containers that are more than ____________ must not be stored, handled, or used indoors - answer 16.4 oz 29. Cng containers with a capacity greater than ____________ must not stored, handled, or used on the roof - answer 8.7 scf 30. Use of lpg/propane on an occupied roof requires an ____________________ from licensed professional ___________________ stating the roof is constructed of ________________________ - answer affidavit, architect or engineer, non-combustible materials 31. Any single standard portable lpg container must not exceed _______________ in weight - answer 100 lbs 32. Any single cng container must not exceed ______________ scf - answer 381 33. Such permit authorizes the permit holder to store, handle, or use flammable gases, or conduct a torch operation at a specific premises or location called? - answer site-specific permit 34. A ____________________________ may be a permanent permit or a temporary permit. - answer site-specific permit 35. Under _______________________________ a permanent permits are valid for ___________only - answer site-specific permit, 12 months 36. Under ________________________a temporary permit may be valid from _______to____________ depends on the construction/operation need. - answer site-specific permit, 1 day to 12 months 37. Such permit authorizes the permit holder to store, handle, use or sell hazardous material or conduct an operation on a citywide basis is called? - answer citywide permit 38. Such permit is valid to temporarily store, handle, use or sell hazardous materials or to conduct an operation at one or more locations is called? - answer citywide permit 39. Citywide permit the duration of such activity at any individual location does not exceed __________________ days - answer 30 calendar 40. Periods of activity in excess 30 calendar days at any one location shall require a __________________________ - answer site-specific permit 41. What should be readily available on the premise for inspection by fire department representatives? - answer any and all permits 42. Hot work program authorization is not issued by the fdny, it must be signed and issued by the __________________ - answer responsible person 43. Hot work shall be available for inspection by any representative for ______________ after the work is completed - answer 48 hours 44. For hot work operation with citywide permit, the owner of the premises of the hot work operation areas must be notified in writing by the citywide permit holder at least ______________ the hot work is to be started - answer 48 hours before 45. Before hot work is authorized and at least _______________ while the authorization is in effect, the hot work area shall be inspected by the responsible person - answer once per day 46. The pre-hot work check must be conducted by the ________________ before hot work is authorized and at least ____________________ - answer responsible person, once per day 47. Hot work area must be kept ___________ feet away from any combustible materials and combustible waste - answer 35 feet 48. All other hot work operations shall be conducted at least _____________ feet away from any combustible materials and combustible waste - answer 25 feet

Show more Read less
Institution
F-60 FIRE GUARD
Course
F-60 FIRE GUARD










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
F-60 FIRE GUARD
Course
F-60 FIRE GUARD

Document information

Uploaded on
September 21, 2025
Number of pages
28
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Content preview

F-60 FIRE GUARD
PRACTICE EXAM QUESTIONS
WITH CORRECT DETAILED
ANSWERS | ALREADY GRADED
A+<RECENT VERSION>



1. The cof holder must keep the cof ___________ or readily available for
inspection - answer upon his or her person


2. Portable lpg containers that are more than ________ must not be stored,
handled, or used indoors. - answer 16.4 oz


3. Permits shall be readily available on the _________ for inspection by fire
department representatives. - answer premises


4. Hot work permits shall be available for inspection by any representative
for __________ after the work is complete. - answer 48 hours


5. For _____________, the owner of the hot work operation areas must be
notified in writing by the citywide permit holder at least 48 hours before
hot work is to be started. - answer citywide hot work operations


6. Pre-hot work checks must be conducted before hot work is authorized
and at least ___________. - answer once per day

,7. Fire watch will be provided for a minimum of _________ after work is
complete. - answer 30 minutes


8. Hot work areas must be kept ___________ feet away from any
combustible material. - answer 35


9. Paper, wood shavings, straw and fabric are examples of
______________. - answer combustible material


10.The entire work area should be checked after completion of hot work for
__________. - answer fires


11.A minimum ____________ rating fire extinguisher must be readily
accessible. - answer 2-a:20-b:c


12.The fire extinguisher must be accessible within __________ feet of hot
work location and fire guard. - answer 30


13.For torch-applied roof systems, a minimum ___________ rating fire
extinguisher must be readily accessible. - answer 3-a: 40-b:c


14.___________ protection systems shall not be shut off while hot work is
performed. - answer automatic sprinkler


15.Compressed gas containers must be replaced when ___________. -
answer they are empty

, 16.Empty containers must be handled in the same manner as ____________.
- answer full ones


17.A ___________ must not be rolled on its side or its rim. - answer
compressed gas container


18.The top of the fire extinguisher must not be more than ________ feet
above the floor, nor the bottom of the fire extinguisher be less than
_________ inches from the ground. - answer 5, 4


19.The cof holder should only consider extinguishing fires when they are
____________. - answer limited in size


20.Never approach a fire from a __________. - answer downwind
direction


21.Do not direct the chemical stream at the ________. - answer center of
the flame


22.For ________, the gas supply must be shut off first and then call 911. -
answer piped gas


23.When not possible to shut off gas supply, allow the flame to
___________ and call 911. - answer burn itself out


24.Class a extinguishers are for extinguishing ___________. - answer
ordinary combustibles


25.Class b extinguishers are for extinguishing ___________. - answer
flammable or combustible liquids
$12.49
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
jervismuthami
4.0
(1)

Get to know the seller

Seller avatar
jervismuthami Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
7
Member since
7 months
Number of followers
0
Documents
559
Last sold
3 weeks ago

4.0

1 reviews

5
0
4
1
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions