quiz 14 with complete solutions
Why do many jurisdictions prefer a static water source for pump performance testing? - ANS
✔Allows for easier evaluation of pump performance
What is the first step in testing the internal intake pressure relief valve? - ANS ✔Connecting a
discharge hoseline from a second pumper
After completion of in-service testing, if any apparatus achieves results less than _____ of its
original capabilities, the D/O should follow all AHJ protocols and procedures for reporting the
failure. - ANS ✔90%
What is the minimum required flow rate from the onboard tank for pumpers with a capacity of
less than 500 gallons (2 000 L)? - ANS ✔250 gpm (1 000 L/min)
When using a flowmeter during pump testing, the D/O must ensure: - ANS ✔proper calibration
to manufacturer's specifications.
Which of the following is NOT included on the test label provided on the pump panel? - ANS
✔Engine manufacturer's contact information
What is net pump discharge pressure (NPDP)? - ANS ✔The difference between intake and
discharge pressure
According to NFPA 1900, the pump certification test label should be affixed: - ANS ✔to the
pump panel.