100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

Journeyman Electrician Practice Test Exam Question & Answers ( Latest 2025).docx

Beoordeling
-
Verkocht
-
Pagina's
20
Cijfer
A+
Geüpload op
18-09-2025
Geschreven in
2025/2026

Journeyman Electrician Practice Test Exam Question & Answers ( Latest 2025).docx

Instelling
Push And Pull Factors Exa Question & Answer ( La
Vak
Push and Pull Factors Exa Question & Answer ( La










Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Push and Pull Factors Exa Question & Answer ( La
Vak
Push and Pull Factors Exa Question & Answer ( La

Documentinformatie

Geüpload op
18 september 2025
Aantal pagina's
20
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

Journeyman Electrician Practice Test
Exam Question & Answers ( Latest 2025)
Conductors with _____ marked on the insulation are NOT approved for
use in a wet location. - CORRECT ANSWERS ✔✔THHN


conductors with THHN insulation are approved for use in dry and damp
locations only and conductors with THWN, THHW, and THW insulation
are recognized for use in dry and wet locations.


Given: A one-family dwelling unit with a demand load of 200 amperes is
supplied with a 120/240 volt, single-phase, electrical system from the
local utility company. What is the MINIMUM size aluminum THW
conductors required for use as service-entrance conductors for this
residence? - CORRECT ANSWERS ✔✔4/0 AWG


one-family dwelling 120/240 volt, single-phase, service-entrance
conductors to be sized at an ampacity of not less than 83% of the
service rating. Therefore, 200 amperes x 83% = 166 amperes; size 4/0
AWG THW aluminum conductors with an allowable ampacity of 180
amperes should be selected for this dwelling.


Where a 150 kVA, single-phase transformer having a secondary voltage
of 120/240 is installed at a multi-family dwelling, the full-load current
rating, in amperes, of the secondary is _____. - CORRECT ANSWERS
✔✔625 amperes

,Journeyman Electrician Practice Test
Exam Question & Answers ( Latest 2025)
To find the full-load current rating of the single-phase transformer
apply the single-phase current formula as shown:I = (150 kVA x 1000) /
240 volts = 15,000/240 = 625 amperes


Which one of the following listed circuit breakers is NOT a standard
ampere rating? - CORRECT ANSWERS ✔✔75 amperes


the standard ampere ratings for fuses and circuit breakers. A circuit
breaker with an ampere rating of 75 amperes is not a standard ampere
rating.


The MINIMUM length of free conductor to be left at each junction box
for the purpose of splicing conductors, or making connections to
illuminares or devices shall be _____ . - CORRECT ANSWERS ✔✔6
inches


free conductor is to be left at each junction box for splices or the
connection of luminaires or devices. The intent of this rule is to ensure
enough conductor slack for the terminal connections or splices to be
made easily.


In general, overhead service-drop conductors shall NOT be smaller than
_____. - CORRECT ANSWERS ✔✔8 AWG copper

, Journeyman Electrician Practice Test
Exam Question & Answers ( Latest 2025)
overhead service-drop conductors to be not smaller than 8 AWG
copper or 6 AWG aluminum or copper-clad aluminum. Do not get
service-drop conductors, the overhead conductors between the utility
electric supply system and the service point, confused with the service-
entrance conductors, the conductors from the service point from the
utility company to the service disconnecting means.


When a galvanized eye-bolt is to be used as the point of attachment for
an electrical service, the NEC requires the eye-bolt to be installed NOT
less than _____ above finished grade. - CORRECT ANSWERS ✔✔10
ft.


provide adequate vertical clearance of the conductors and prevent
physical damage to the conductors and prevent persons from making
accidental contact with the conductors which may create a shock
hazard or electrocution. In no case shall the point of attachment of the
service-drop conductors to be less than 10 ft. above finished grade.


Why is electrical continuity required for metallic conduit? - CORRECT
ANSWERS ✔✔To establish an effective ground-fault path and
facilitate the operation of the over-current protective device.


Electrical continuity is required for metallic conduit to establish an
effective ground-fault path and facilitate the operation of the
overcurrent protective device.

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
NatashaKate Florida A&M University
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
16
Lid sinds
1 jaar
Aantal volgers
0
Documenten
2618
Laatst verkocht
1 maand geleden
Natashakate

1.0

1 beoordelingen

5
0
4
0
3
0
2
0
1
1

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Veelgestelde vragen