100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

Nicety level 1 Study Guide questions & Answers ( Latest Exams 2025 ).docx

Rating
-
Sold
-
Pages
24
Grade
A+
Uploaded on
14-09-2025
Written in
2025/2026

Nicety level 1 Study Guide questions & Answers ( Latest Exams 2025 ).docx

Institution
DMV Motorcycle Permit Tes Exa Question & Answer
Course
DMV Motorcycle Permit Tes Exa Question & Answer










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
DMV Motorcycle Permit Tes Exa Question & Answer
Course
DMV Motorcycle Permit Tes Exa Question & Answer

Document information

Uploaded on
September 14, 2025
Number of pages
24
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Nicety level 1 Study Guide questions &
Answers ( Latest Exams 2025 )
When testing a water level supervisory switch serving a pressure tank a signal
shall indicate if the water level _____________from the required level


(NFPA 72, Table 14.4.3.2 17 (j) (4) - CORRECT ANSWERS ✔✔rises or falls over
3 inches


If combination audible/visible appliances are installed the location of the installed
appliance shall be determined by the requirements of _______.


(Nfpa 72 18.4.8.1) - CORRECT ANSWERS ✔✔the visible appliance


What is the maximum number of 12 gauge THHN wires that can be installed in 1"
EMT?


(Nec Annex C tables) - CORRECT ANSWERS ✔✔26


Two resistors are connected in parallel. R1 = 300 Ohms, R2 = 300 Ohms. What is
their equivalent resistance? - CORRECT ANSWERS ✔✔150 ohms


A Room is 200' long and 150' wide and the 8' high ceiling is smooth and flat. A
spot type heat detector has been selected that is listed for a 50' maximum
spacing between detectors. According to NFPA 72 how many detectors will be
needed to protect this room?


x = - CORRECT ANSWERS ✔✔12

,Nicety level 1 Study Guide questions &
Answers ( Latest Exams 2025 )
According to NFPA 72 the minimum number of restorable fixed temperature spot
type heat detectors that must be tested during each annual test is?


(NFPA 72 14.4.4.5.1) - CORRECT ANSWERS ✔✔Two detectors or more on
each initiating device circuit


According to NFPA 72 how many spot type heat detectors are required for a space
that is 80' long and 55 floor wide with a smooth 10' ceiling? the detector is listed
for a maximum space between detectors of 30' - CORRECT ANSWERS ✔✔6


What color code requirement for a spot type heat detector rated at 200 ゚ F -
CORRECT ANSWERS ✔✔White (NFPA 72, Table 17.6.2.1)


Unless otherwise recommended by the manufacturers published instructions
single and multiple stations smoke alarms installed in one and 2 family dwellings
shall be replaced every - CORRECT ANSWERS ✔✔10 years from the day-of
manufacture. (NFPA 72, 14.4.7.1)


Fire alarm cables are permitted to be strapped to conduit to support the cable -
CORRECT ANSWERS ✔✔False (NEC 760.143)


Where non power limited wiring is installed exposed it must be mechanically
protected within_____of the finished floor - CORRECT ANSWERS ✔✔7' ft


Fire-Warning equipment to be installed in residential occupancies shall produce
the audible emergency evacuation signal described in - CORRECT ANSWERS
✔✔ANSI S3.41

, Nicety level 1 Study Guide questions &
Answers ( Latest Exams 2025 )

According to NFPA 72, visible notification appliance for non-sleeping areas must
be mounted between ___ and ___ inches above the finished floor - CORRECT
ANSWERS ✔✔80 & 96


If system impairment occurs, the owner must be notified ___ within ___ -
CORRECT ANSWERS ✔✔in writing & within 24 hours


A 20 X 20' ft room with a 20'ft high ceiling requires at a minimum a ___ ceiling
mounted strobe - CORRECT ANSWERS ✔✔30 candela


According to NFPA 72, a 40 x 40'ft room or area with a 10'ft ceiling is best covered
by a ___ cd visible notification appliance, centered on one wall. - CORRECT
ANSWERS ✔✔60


Conductors returning to the fire alarm control panel (FACP) from the last field
device on the circuit might indicate a _____ circuit - CORRECT ANSWERS
✔✔Class A


Secondary power supplies for an emergency voice/alarm communication fire
alarm system shall be capable of operating for minimum of ___ of standby
followed by ___ of alarm. - CORRECT ANSWERS ✔✔24 hrs & 15 mins


The fire alarm system primary power branch circuit disconnecting means must be
___ in color. - CORRECT ANSWERS ✔✔Red

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
NatashaKate Florida A&M University
View profile
Follow You need to be logged in order to follow users or courses
Sold
16
Member since
1 year
Number of followers
0
Documents
2618
Last sold
1 month ago
Natashakate

1.0

1 reviews

5
0
4
0
3
0
2
0
1
1

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions