This document provides practice questions and answers for Electrical Level 3, Chapter 1, focusing on load calculations and branch circuit requirements according to the NEC®. It covers continuous and noncontinuous loads, receptacle requirements, general lighting load calculations, show window receptacles, small appliance branch circuits, voltage drop calculations, motor full-load currents, heating equipment, and demand factors for residential and commercial cooking appliances. The material is structured in Q&A format, making it a practical study guide for electricians and apprentice

Show more Read less
Institution
Electrical Level 3 Module 1
Course
Electrical Level 3 Module 1








Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Electrical Level 3 Module 1
Course
Electrical Level 3 Module 1

Document information

Uploaded on
September 8, 2025
Number of pages
3
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Content preview

Electrical-Level 3, Chapter 1


A continuous load has a maximum current of 25A. What is the minimum rating of the
branch circuit that can be​installed? - ANS - 40A

A continuous load is defined by the NEC​® as a load whose maximum current is
expected to continue for at least​_____. - ANS - 3 hours

A warehouse has​12,500 ft2 of floor area. What is the estimated general lighting load in​
VA? - ANS - ​3,125

At a​minimum, a 60' long show window would need​_____ receptacles. - ANS - 5

Branch circuit conductors supplying continuous duty loads are calculated at​_____. -
ANS - 25% of the rated load

How many receptacle outlets in a​dentist's office can be connected to a​20A,
single-phase 120V circuit if all of the outlets will supply noncontinuous​loads? (Note:
NEC Section​220.14(I) assigns a load of 180VA to each nonresidential​outlet.) - ANS -
13

How many receptacles are required for 90 linear feet of show window​area? - ANS - 8

Load calculations for circuits supplying lighting units with ballasts are based upon​
_____. - ANS - the ampere ratings of the ballasts

The general lighting load​(expressed as a unit load per square​foot) for a warehouse is​
_____. - ANS - 1/4VA/sq ft

The general lighting load for a store is​_____. - ANS - 3VA/sq ft

The load for 6 of​multi-outlet assembly used simultaneously is​_____. - ANS -
​1,080VA

The voltage drop between the point of service and the farthest outlet in a branch circuit
should not exceed​_____. - ANS - ​3%

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
janenurse Chamberlain College Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
256
Member since
2 year
Number of followers
221
Documents
2462
Last sold
2 months ago

4.1

45 reviews

5
30
4
3
3
5
2
2
1
5

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions