, 1. air gap EXPLANATION the vertical distance between the opening of the water supply and the flood level rim
of a receptacle
2. branch EXPLANATION any part of the piping system other than a main, riser or stack
3. Branch vent EXPLANATION A vent connecting one or more individual vents with a vent stack or stack vent
4. Building Drain EXPLANATION is the lowest part of the drainage system which receives waste from soil and
waste pipes and connects to the building sewer
5. Building sewer EXPLANATION is drainage piping that conveys waste from the building drain to the public sewer
or disposal system
6. Cleanout EXPLANATION Access opening in the drainage system used to remove obstructions
7. Combination fixture EXPLANATION Two or three compartment sink drained by a continuous waste connected
to one trap
8. Combination Waste and Vent system EXPLANATION A horizontal wet venting system for sinks and floor drains
9. Common Vent EXPLANATION A single vent serving as the vent for two fixture drains
10. critical level EXPLANATION is an elevation mark on a vacuum breaker setting the minimum elevation the
device can be installed above the flood level rim of a fixture
11. cross-connection EXPLANATION is an actual or potential tie between potable water and any source of
pollution or contamination
12. Developed Length EXPLANATION A measurement of piping taken along the centerline of pipe and fittings
13. drain EXPLANATION Any pipe that conveys waste water in the drainage system
14. Indirect Waste EXPLANATION Is waste pipe that drains through an air gap to the drainage system
15. Individual vent EXPLANATION A pipe installed to vent one fixture trap. It may connect to the vent system
above the fixture or terminate in the open air.
16. main EXPLANATION Is the primary or principal pipe to which branches are connected
17. potable water EXPLANATION Is water that is sufficiently free of impurities to meet public health standards
18. Rough in EXPLANATION Parts of the plumbing system that are installed prior to the installation of fixtures.
19. Soil Pipe EXPLANATION Is drain pipe conveying sewage containing fecal matter
20. Stack Vent EXPLANATION The extension of a soil or waste stack above the highest fixture served
21. trap EXPLANATION Is a device that provides a water seal to prevent the passage of sewer gas and allow the
passage of waste
22. Trap seal EXPLANATION distance from weir to top of the dip of the trap
23. Vacuum Breaker EXPLANATION is a backflow preventer that allows air to a vacuum being pulled on a
system