Examples of extinguishers for protecting class B hazards are
A. aqueous film forming foam
B. Carbon dioxide
c.Wet chemical
d. A and B only
E. all the above
- Correct Answer :D. A and B only
A church is classified as what type of hazard?
A. light(low) hazard
B.Ordinary(moderate) hazard
C. Extra(high) hazard
D. Special(unusual) hazard
- Correct Answer :A. Light hazard
A parking garage is classified as what type of hazard?
A. light(low) hazard
B.Ordinary(moderate) hazard
C. Extra(high) hazard
D. Special(unusual) hazard
- Correct Answer :B. ordinary
A boat or aircraft servicing is classified as what type of hazard?
A. light(low) hazard
B.Ordinary(moderate) hazard
C. Extra(high) hazard
D. Special(unusual) hazard –
Correct Answer :C. extra
Building protection should be provided by fire extinguishers suitable for what class of fire
extinguishers?
A+ TEST BANK 1
, NFPA 1006 Exam
A. Class a
B class B
C. class C
D. All the above
- Correct Answer :D. All the above
An ordinary hazard occupancy is also designated as a ______ hazard occupancy
A. normal
B. significant
c. medium
D. moderate
- Correct Answer :D. moderate
The minimum rated single fire extinguisher for an Extra Class A hazard occupancy
A.2-A
b. 2-A 10 BC
C. 4-A
D. 4-A 10BC
- Correct Answer :C. 4-A
The maximum floor area per unit of a rating for an Ordinary Class A Hazard Occupancy is
A.1000 sq ft
B.1500 sq ft
C. 2000 sq ft
D.2500 sq ft
- Correct Answer :A. 1000 sq ft
The maximum travel distance to an 80-B extinguisher for an Extra B hazard is
A.30 ftt
B.50 ft
C. 75 ft
D.100 ft
- Correct Answer :B. 50 ft
Who is responsible to ensure that proper maintenance, inspection, and recharging is conducted
for all five extinguishers in the premises
A.Fire dept
A+ TEST BANK 2
, NFPA 1006 Exam
B.authority having jurisdiction
C. owner
D.service technician
- Correct Answer :C. owner
Carbon dioxide hose assemblies that pass the conductivity test shall have the test information
recorded on a label that is attached to the
A.fire extinguisher
B.carrying handle
C. hose assembly
D.Discharge lever –
Correct Answer :hose assembly
Internal examination of the extinguisher is a required procedure during the annual maintenance
for which of the following type of extinguisher
A.stored pressure dry chemical
B.Cartridge operated dry chemical
C. Carbon dioxide
D.None of the above
- Correct Answer :B. cartridge operated dry chemical
Which of the following type of fire extinguisher does not require a six year internal
maintenance?
A. cartridge operated dry chemical
B.stored pressure dry powder
C. stored pressure halogenated agent
D.stored pressure water
- Correct Answer :d. stored pressure water
Which of the following type of extinguishers does not require a "verification of service" collar
A.Cartridge operated dry chemical
B.Class K
C. Pressurized water
D.Stored pressure wheeled –
Correct Answer :A Cartridge operated dry chemical
Which of the following is not justification for condemning a cylinder during the visual
examination
A+ TEST BANK 3
, NFPA 1006 Exam
A.the extinguisher shows evidence of being burned in a fire
B.there is pitting under a removable nameplate
C. the paint on the cylinder is peeling away
D.The fire extinguisher was used to dispel an insecticide
- Correct Answer :C. the paint on the cylinder is peeling away
When a fire extinguisher cylinder, shell, or cartridge must be condemned because it fails
hydrostatic pressure test of fails to pass visual examination, which of the following procedures
must be performed
A.CONDEMNED must be stamped on the sylinder
B.the owner must be notified that the cylinder may not be reused
C. The owner mist be notified in writing that the cylinder is condemned
D.All the above
- Correct Answer :D. all the above
What is the correct hydrostatic test pressure for a stored pressure dry chemical fire
extinguisher?
A.300 psi
B.5/3 times the operating pressure
C. 2 time the operating pressure
D.None of the above –
Correct Answer :A. 300 psi
What is the minimum frequency for calibrating the master pressure gauges used for hydrostatic
testing of fire extinguisher cylinders, shells, and accessories
A.Quarterly
B.Semi-annually
C. Annually
D.None of the above
- Correct Answer :B. semi annually
A three dimensional fire often involves static flammable liquid
True
False - Correct Answer :False
Which hazardous material is commonly found in vehicle batteries?
A) Sulfuric acid
B) Hydrochloric acid
C) Hydrofluoric acid
A+ TEST BANK 4