Questions and Verified ASTM C1064, C172, and Slump
Test Answers
Description: This exam prep document provides 100% verified ACI Grade I questions
and answers. It covers ASTM standards such as C1064 (temperature), C172
(sampling), and detailed slump test procedures. Other topics include air content
determination, curing, rodding, vibration, and equipment requirements. Designed
for technician certification candidates, it ensures comprehensive coverage of field-
testing methods.
The sensor of the temperature measuring device shall be submerged a minimum of
_____ in. [_____mm] into the freshly mixed concrete. - answer✔✔3 in. [75 mm]
The temperature measuring device shall have a capacity of measuring temperature
of freshly mixed concrete to +- _____ degrees F [+- _____ C] throughout a range of
_____. - answer✔✔1 degree F [0.5 C], 30 degrees F to 120 F [0 C to 50 C] The
temperature measuring device shall be calibrated _____, or whenever there is a
question of _____. - answer✔✔Annually, accuracy The temperature of concrete
1
Page
may be measured in a wheelbarrow. True or False? - answer✔✔True The
, temperature of concrete may be measured in a wall form. True of False -
answer✔✔True A composite sample of concrete is required even if the only
purpose for obtaining the sample is to determine temperature. True of False? -
answer✔✔False What must be done to the sample container prior to sampling
the concrete? - answer✔✔Dampen (with water) What must be done to the
concrete surrounding the temperature measuring device after the device is
submerged in the fresh concrete. - answer✔✔Gently press the concrete around
the temperature measuring device at the surface of the concrete How long must the
temperature measuring device remain in the freshly mixed concrete? -
answer✔✔At least 2 minutes but not more than 5 minutes After the temperature
of the concrete is read, what is required? - answer✔✔Reporting of temperature
The temperature of concrete is reported to the nearest _____ degrees F [_____ C] -
answer✔✔1 degree F [0.5 C] According to ASTM C1064, what is one reason to
take the temperature of concrete? - answer✔✔Verify conformance to a specified
requirement for temperature of concrete A maximum temperature of freshly mixed
concrete is specified in ASTM C1064. True of False? - answer✔✔False The sample
of concrete used for temperature determination must be rodded 25 times. True or
False? - answer✔✔False Sampling by this method is required when tests are to be
made to determine _____ with specification requirements. -
answer✔✔Compliance This method covers sampling from four types of mixtures
2
which are _____, _____, _____, and _____. - answer✔✔Stationary mixers, paving
Page