Questions And Answers
When estimating how much fabric will be required for custom
designed draperies, which of the following will you need to
consider when determining the total fabric width needed?
A the amount of fullness of the drapery, the opening size
B the opening size, the amount of fullness, the return
C the return, the opening size, the stacking space
D all of these -
correct answer D. all of these // In estimating fabric for
draperies, the total fabric width must be determined. This is the
total of the opening size, the stacking space, the return, any overlap
of two sections of drapery, and the amount of fullness of the
drapery.
What is the maximum height of an accessible (barrier free) sink?
36" (900 mm)
34" (865 mm)
30" (750 mm)
27" (685 mm) -
correct answer B. 34" // NCIDQ 5.2 ALL accessible (barrier-free)
countertops, sinks, reception/transaction surfaces, and other
horizontal work surfaces MUST NOT exceed 34″ (865 mm) AFF with
a 27″H (685 mm) clear knee space below.
,NCIDQ IDPX and IDFX Practice Exam
Questions And Answers
ADA.gov 606.3 Height. Lavatories and sinks shall be installed with
the front of the higher of the rim or counter surface 34 inches (865
mm) maximum above the finish floor or ground.
306.3.3 Minimum Required Depth. Where knee clearance is
required under an element as part of a clear floor space, the knee
clearance shall be 11 inches (280 mm) deep minimum at 9 inches
(230 mm) above the finish floor or ground, and 8 inches (205 mm)
deep minimum at 27 inches (685 mm) above the finish floor or
ground.
A $OSS switch indicates what?
daylight sensor
remote controlled switch
one single switch
occupancy sensor/switch combination -
correct answer D. occupancy sensor/switch combination //
Refer to your drawing legend, as symbols used may vary from what
you are accustomed to, and could possibly vary from test to test.
This is the symbol provided on a typical NCIDQ drawing that
indicates occupancy sensor/switch combination.
, NCIDQ IDPX and IDFX Practice Exam
Questions And Answers
What is minimum clear width of the doorway and maximum size of
an egress door?
34 clear width and 36 door leaf
32 clear width and 48 door leaf
34 clear width and 48 door leaf
30 clear width and 36 door leaf -
correct answer B. 32 clear width and 48 door leaf //
International Building Code 1008.1.1 Size of doors. The minimum
width of each door opening...shall provide a clear width of 32
inches (813 mm). Clear openings of doorways with swinging doors
shall be measured between the face of the door and the stop, with
the door open 90 degrees (1.57 rad). Where this section requires a
minimum clear width of 32 inches (813 mm) one leaf shall provide
a clear opening width of 32 inches (813 mm). The maximum width
of a swinging door leaf shall be 48 inches (1219 mm) nominal.
When selecting the upholstery and window treatment fabrics for a
hotel lobby design, which of the following standards would NOT be
a consideration for the fabric?
Cigarette Ignition Resistance Test of Furniture components
NFPA 257