A small subdivision into which large areas are divided to
permit selective access to some while maintaining other zones
secure defines what? - ----Answers----a zone
A good device or location to program as a zone type 2 is? - ---
-Answers----Overhead garage door
A smoke detector should be programmed as what zone type? -
----Answers----Type 9
True or False? If a device programmed as Type 22 is tripped, it
will activate the bell/siren cicruit. - ----Answers----False
(Type 22 is a silent alarm)
What type of detector will detect an opening in a ceiling door
or wall? - ----Answers----Perimiter
True or False? When using a normally closed contact, a
protective loop will open during an alarm event. - ----
Answers----False
,True or False? A normally open contact will allow potential to
move through the contact when under the influence of a
magnetic field. - ----Answers----True
Windows located more than 18 feet above the ground or other
roofs are considered _____. - ----Answers----Inaccessible
True or False? An intruder entering a premise through a
broken window would be detected if a magnetic contact were
installed on the window. - ----Answers----False
(The window would remain closed and wouldn't trip the sensor
which is why glass break detectors are a thing)
When installing a magnetic contact on a movable window, the
_______ must be placed on the movable portion of the window.
- ----Answers----magnet
_____ should be installed in front of and within range of the
windows they are designed to protect. - ----Answers----
Glass break sensors
True or False? Smoke alarms are more commonly used by
home builders due to their increased sensitivity. - ----
Answers----False
A smoke _____ is connected to a circuit which is connected to
an alarm panel. - ----Answers----detector
, True or False? If a siren is "integral" to the burglar alarm
panel, it is not built-in to the panel. - ----Answers----False
The "temporal 3 or T3" audible notification pattern is used to
indicate what type of notification? - ----Answers----Fire
Emergency
According to NFPA 72, when using a decibel meter to test
proper audible notification levels in a sleeping room, the door
to the sleeping room must be? - ----Answers----Closed
According to standard UL 68(1), removable covers of plates of
conduit boxes or junction boxes shall be electrically tampered
or permanently secured with _____-way screws or similar type
fastening device. - ----Answers----1-way screws
A general emergency, mass notification system is used to
warn the public of what? - ----Answers----Severe weather
A _____ is used to reduce standard commercial supply voltage
to a lower voltage for use by an alarm system. - ----Answers-
---transformer
True or False? The primary voltage of a step-down
transformer will have a higher voltage than the secondary
voltage. - ----Answers----True