Which of the following balancing control modes is used by PJM under normal operations? - ANS Tie-Line Bias Which of the following influences does PJM consider when performing their system load forecast? - ANS Weather Conditions & Day of the Week All of the following are limits that must be submitted to PJM for generating units EXCEPT: 1. Eco Min 2. Eco Max 3. Emergency Max 4. Dynamic Instability - ANS Dynamic Instability If PJM experienced an event that caused the loss of a 1,000 MW generator, which of the following would most likely provide the quickest impact to improve the undegenerating Area Control Area (ACE)? 1. Remedial Action Reserve 2. Synch Reserve 3. Non-Synch Reserve 4. Secondary Reserve - ANS Synch Reserve PJM TEST EXAM 2025 QUESTIONS AND ANSWERS Copyright ©2025 BRIGHTSTARS ALL RIGHTS RESERVED 2 Your system has experienced an event that caused the frequency to drop below 60.00 Hz, what would be the most likely event that occurred? - ANS A generator on your system tripped offline How does the PJM dispatcher inform the Members of the PJM regulation Requirements? - ANS All-Call In order for your generator to quality to supply regulation in the PJM Regulation market, it must be able to respond and attain its desired output within how many minutes? - ANS 5 minutes Based on a generator capability curve, in order to maximize the MVAR output of the generator, it may be necessary to: - ANS decrease the MW output of the unit PJM maintains a regulation quality standard which states that a generator may be certified to provide regulation only after it achieves three consecutive regulation test scores of at least - ANS 75% Which of the following would NOT be a cause for a sudden deviation in the balancing area ACE? 1. incorrect interchange number 2. loss of a tie-line RTU 3. loss of internal load 4. loss of adjacent control area generation - ANS loss of adjacent control area generation The primary purpose for the balancing area to have Regulation is to correct for: - ANS small deviations in load It is necessary for Generation Owner dispatchers to notify PJM of unplanned unit outages: - ANS as soon as practicable PJM should be made aware of any fuel shortage that a generator may experience. Copyright ©2025 BRIGHTSTARS ALL RIGHTS RESERVED 3 This information assists in analyzing the resources and reliably operating the system. A heightened awareness is expected during: - ANS extreme hot or cold conditions Generators are required to obtain PJM approval prior to removing a generating unit from service. The only exception is for: - ANS injury to personnel will be prevented Prior to removing a self-scheduled generator from service, the PJM member must first - ANS give PJM the option to takeover the unit for the market When PJM experiences problems with their primary digital control signal, it sometimes becomes necessary for companies with the capability, to switch to the back-up signal. This backup signal is known as: - ANS Analog control When PJM sends cost signals to generators, to provide direction for increasing or decreasing the facility output, this signal that is sent is known as: - ANS Dispatch Rate Under normal operating conditions, what is the limit that will provide the lowest output level of a generating unit? - ANS Eco Min When PJM send out a cost signal to generators to adjust their output, the generating personnel adjust the output of the unit base on the unit's - ANS price or cost curve incremental Which eSuite tool is used to maintain individual generator regulation data that is submitted by PJM members? - ANS eMarket PJM's ACE configur

Show more Read less
Institution
PJM
Course
PJM











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
PJM
Course
PJM

Document information

Uploaded on
July 3, 2025
Number of pages
35
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

PJM TEST EXAM 2025 QUESTIONS AND
ANSWERS


Which of the following balancing control modes is used by PJM under normal operations? -
ANS Tie-Line Bias


Which of the following influences does PJM consider when performing their system load
forecast? - ANS Weather Conditions & Day of the Week


All of the following are limits that must be submitted to PJM for generating units EXCEPT:


1. Eco Min
2. Eco Max
3. Emergency Max

4. Dynamic Instability - ANS Dynamic Instability


If PJM experienced an event that caused the loss of a 1,000 MW generator, which of the
following would most likely provide the quickest impact to improve the undegenerating Area
Control Area (ACE)?


1. Remedial Action Reserve
2. Synch Reserve
3. Non-Synch Reserve

4. Secondary Reserve - ANS Synch Reserve




Copyright ©2025 BRIGHTSTARS ALL RIGHTS RESERVED 1

,Your system has experienced an event that caused the frequency to drop below 60.00 Hz, what
would be the most likely event that occurred? - ANS A generator on your system tripped
offline


How does the PJM dispatcher inform the Members of the PJM regulation Requirements? -
ANS All-Call


In order for your generator to quality to supply regulation in the PJM Regulation market, it must
be able to respond and attain its desired output within how many minutes? - ANS 5 minutes


Based on a generator capability curve, in order to maximize the MVAR output of the generator,
it may be necessary to: - ANS decrease the MW output of the unit


PJM maintains a regulation quality standard which states that a generator may be certified to
provide regulation only after it achieves three consecutive regulation test scores of at least -
ANS 75%


Which of the following would NOT be a cause for a sudden deviation in the balancing area ACE?


1. incorrect interchange number
2. loss of a tie-line RTU
3. loss of internal load

4. loss of adjacent control area generation - ANS loss of adjacent control area generation


The primary purpose for the balancing area to have Regulation is to correct for: - ANS small
deviations in load


It is necessary for Generation Owner dispatchers to notify PJM of unplanned unit outages: -
ANS as soon as practicable


PJM should be made aware of any fuel shortage that a generator may experience.

Copyright ©2025 BRIGHTSTARS ALL RIGHTS RESERVED 2

,This information assists in analyzing the resources and reliably operating the system. A
heightened awareness is expected during: - ANS extreme hot or cold conditions


Generators are required to obtain PJM approval prior to removing a generating unit from
service.


The only exception is for: - ANS injury to personnel will be prevented


Prior to removing a self-scheduled generator from service, the PJM member must first -
ANS give PJM the option to takeover the unit for the market


When PJM experiences problems with their primary digital control signal, it sometimes
becomes necessary for companies with the capability, to switch to the back-up signal.


This backup signal is known as: - ANS Analog control


When PJM sends cost signals to generators, to provide direction for increasing or decreasing
the facility output, this signal that is sent is known as: - ANS Dispatch Rate


Under normal operating conditions, what is the limit that will provide the lowest output level of
a generating unit? - ANS Eco Min


When PJM send out a cost signal to generators to adjust their output, the generating personnel
adjust the output of the unit base on the unit's - ANS price or cost curve incremental


Which eSuite tool is used to maintain individual generator regulation data that is submitted by
PJM members? - ANS eMarket


PJM's ACE configuration is such, that when the ACE is positive (+), it indicates - ANS too much
generation

Copyright ©2025 BRIGHTSTARS ALL RIGHTS RESERVED 3

, If a generator is self-scheduled, what is the minimum notification time required in order for the
MW output to be adjusted? - ANS 20 minutes prior to the change


When corrections are made for the time error and the system scheduled frequency must be
changed to implement the correction, how much is the frequency scheduled adjusted by? -
ANS + /- 0.02 Hz


When PJM runs their Regulation test, how long do the tests normally run? - ANS 40 minutes


Your system has a 300 MW steam unit, but due to oil deliveries, the on-site fuel supply is
diminishing.


What is the hourly threshold for reporting to PJM that the unit cannot operate at its maximum
capacity due to the fuel limitation? - ANS 72 hours


What is the regulation requirement for the PJM balancing area during on-peak hours? -
ANS 1.0% of the forecasted peak load


What is the time requirement that a generator that wishes to self-schedule itself must provide
to PJM? - ANS 20 minutes


The PJM Peak Period Maintenance season occurs: - ANS Between the 24th & 36th
Wednesdays of the year


Maintenance outage extensions may be granted provided that the request for an extension is
made - ANS Prior to the end of the outage


What is the maximum time limit for the maintenance outages that occur during the PJM Peak
Period Maintenance season? - ANS 9 days




Copyright ©2025 BRIGHTSTARS ALL RIGHTS RESERVED 4

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Brightstars Havard School
View profile
Follow You need to be logged in order to follow users or courses
Sold
197
Member since
1 year
Number of followers
7
Documents
12560
Last sold
5 days ago
VERIFIED EXAMS AND STUDY GUIDES.

Here, you will find Study Notes, Exam answer packs 100% Guarenteed success.

3.3

31 reviews

5
10
4
4
3
8
2
3
1
6

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions