) Practice Questions &
Answers | Grade A | 100% Correct
Question:
Guidelines from which of the following code sets are included as part of the
code set requirements under HIPAA?
A. CPT® Category III codes
B. ICD-10-CM
C. HCPCS Level II
D. ADA Dental Codes
Answer:
B. ICD-10-CM
,Question:
Which of the following is an example of electronic data?
A. A digital X-ray
B. An explanation of benefits
C. An advance beneficiary notice
D. A written prescription
Answer:
A. A digital X-ray
Question:
PREOPERATIVE DIAGNOSIS: Displaced impacted Colles fracture, left distal
radius and ulna.
POSTOPERATIVE DIAGNOSIS: Displaced impacted Colles fracture, left
distal radius and ulna.
PROCEDURE: Reduction with application of an external fixation system, left
wrist fracture
INDICATIONS: The patient is a 46 year-old right-hand-dominant female who
fell off stairs 4 to 5 days ago sustaining an impacted distal radius fracture with
possible intraarticular component and an associated ulnar styloid fracture.
,Today in surgery, fracture was reduced anatomically and an external fixation
system was applied.
PROCEDURE DESCRIPTION: Under satisfactory general anesthesia, the
fracture was manipulated and C-arm images were checked. The left upper
extremity was prepped and draped in the usual sterile orthopedic fashion.
Two small incisions were made over the second metacarpal and after
removing soft tissues including tendinous structu
Answer:
B. 25605- LT, 20690-51
Question:
Preoperative Diagnosis: Syncope. Symptomatic Bradycardia.
Postoperative Diagnosis: Bradycardia
Procedure: Insertion DDD Pacemaker
Anesthesia: Moderate Sedation
Procedure Description: Left subclavian venipuncture was carried out. A guide
wire was passed through the needle, and the needle was withdrawn. A second
subclavian venipuncture was performed, a second guide wire was passed and
the second needle was withdrawn. An oblique incision in the deltopectoral
area incorporating the wire exit sites. A subcutaneous pocket was created with
, the cautery on the pectoralis fascia. An introducer dilator was passed over the
first wire and the wire and dilator were withdrawn. A ventricular lead was
passed through the introducer, and the introducer was broken away in the
routine fashion. A second introducer dilator was passed over the second guide
wire and the wire and dilator were withdrawn. An atrial lead was passed
through
Answer:
A. 33208
Question:
PREOPERATIVE DIAGNOSIS: Diverticulitis, perforated diverticula
POST OPERATIVE DIAGNOSIS: Diverticulitis, perforated diverticula
PROCEDURE: Hartmann procedure, which is a sigmoid resection with
Hartmann pouch and colostomy.
DESCRIPTION OF THE PROCEDURE: Patient was prepped and draped in
the supine position under general anesthesia. Prior to surgery patient was
given 4.5 grams of Zosyn and Rocephin IV piggyback. A lower midline
incision was made, abdomen was entered. Upon entry into the abdomen,
there was an inflammatory mass in the pelvis and there was a large abscessed
cavity, but no feces. The abscess cavity was drained and irrigated out. The left
colon was immobilized, taken down the lateral perineal attachments. The
sigmoid colon was mobilized. There was an inflammatory mass right at the
area of the sigmoid colon consistent with a diverticulitis or perforation with
infection. Proximal to this in the distal l