100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4,6 TrustPilot
logo-home
Exam (elaborations)

ICC CALIFORNIA UST INSPECTOR Exam Questions and Correct Detailed Answers

Rating
-
Sold
-
Pages
208
Grade
A+
Uploaded on
24-06-2025
Written in
2024/2025

ICC CALIFORNIA UST INSPECTOR Exam Questions and Correct Detailed Answers

Institution
ICC CALIFORNIA UST INSPECTOR
Course
ICC CALIFORNIA UST INSPECTOR











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
ICC CALIFORNIA UST INSPECTOR
Course
ICC CALIFORNIA UST INSPECTOR

Document information

Uploaded on
June 24, 2025
Number of pages
208
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

ICC CALIFORNIA UST INSPECTOR Exam
Questions and Correct Detailed Answers
(Verified Answers) Already Graded A+
Guaranteed Pass Latest Versions 2025


If a UST system is utilizing an overfill alarm, the alarm must be triggered to alert
the transfer operator when the tank is no more than full
a.) 85%
b.) 95%
b.) 90%
c.) 80%
c.) 90%




An automatic tank gauge is utilized for leak detection of the .
a.) Tank
b.) Tank and Piping
c.) Piping
d.) Interstitial space
a.) Tank
CCR Title 23, Sec 2643(b)(1)




After completion of enhanced leak detection (ELD) test, the ELD test results must

,be submitted to the .
a.) The local agency
b.) The SWRCB
c.) Owner of the UST system
d.) To both the SWRCB and the local agency
b.) To both the SWRCB and the local agency
CCR Title 23, Sec 2644.1(a)(5)



A permit to operate a UST system must have all of the following listed on the
permit, EXCEPT:
a.) The state UST identification number(s)
b.) Name of the tank manufacturer and tank capacity
c.) Permit expiration date
d.) Monitoring requirements
b.) Name of the tank manufacturer and tank capacity
CCR Title 23, Sec 2712(c)




A temporary closure is appropriate for which of the following:
a.) The UST system is empty and will be removed from service indefinitely
b.) The UST system has ceased to store hazardous materials but will be used
within the next 12 consecutive months
c.) The UST system is unable to meet compliance requirements and will be
removed
d.) The UST system has been red-tagged

,b.) The UST system has ceased to store hazardous materials but will be used
within the next 12 consecutive months
CCR Title 23, Sec 2671 & 2670
A local agency determines that a UST facility within the last year had compliance
issues. Prior to issuing a new permit or renewal to operate an UST the local agency
shall:
a.) Ask the state to assist in a joint inspection
b.) Request the owner/operator to submit a "Return to Compliance" form.
c.) Refer to a District Attorney Investigator
d.) Inspect the facility and determine compliance
d.) Inspect the facility and determine compliance
CCR Title 23, Sec 2712(c)




All the following components require third party certification, except:
a.) Automatic tank gauging systems
b.) Statistical inventory reconciliation methods
c.) Spill Containment lids
d.) Liquid phase out-of-tank products
c.) Spill Containment lids




The exterior surface of an underground storage tank must bear a marking or label
which shows the following information, except:
a.) Design pressure in psig
b.) Useable capacity in gallons.

, c.) Width of the interstitial space
d.) Identity of manufacturer
c.) Width of the interstitial space
CCR Title 23, Sec 2631(b)




Which of the following is not a confined space:
a.) A really deep turbine sump
b.) A space not designed for continuous employee occupancy
c.) An area with limited access
d.) An area with limited ventilation
d.) An area with limited ventilation
CCR Title 8, Sec 5157(b)




A secondary containment system which is not an integral part of primary
containment shall be designed and constructed according to an engineering
specification approved by a third party. The secondary containment system shall
contain of the volume of the largest primary container within it,
in the case of multiple primary containers:
a.) 100 percent
b.) 10 percent
c.) 110 percent
d.) 150 percent
d.) 150 percent

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
KGeorge Western Governors University
View profile
Follow You need to be logged in order to follow users or courses
Sold
128
Member since
2 year
Number of followers
25
Documents
4113
Last sold
2 days ago

3.6

27 reviews

5
13
4
1
3
7
2
2
1
4

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can immediately select a different document that better matches what you need.

Pay how you prefer, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card or EFT and download your PDF document instantly.

Student with book image