Under which of these conditions shall the instrument Air Reserve header cylinders be permitted to be stored with the instrument air compressor? A) the mechanical equipment room does not contain a boiler. B) the medical air compressors are in the same room. C) the only motor-driven machinery in the room is for instrument air equipment. D) the room is secured with lockable doors. - ANS C) The only motor-driven machinery in the room is for the instrument air equipment Riser valves are those valves located where? A) adjacent to the main riser downstream of any zone valve. B) anywhere in the lateral branches of the piping system. C) in the mainline adjacent to the base of the riser. D) in the riser adjacent to the mainline. - ANS D) In the riser adjacent to the main line When is the initial pressure test conducted by the installer? A) after blowdown of the distribution piping. B) after installation of alarm sensors. C) before blowdown of distribution piping. D) before installation of station rough in assembly. - ANS A) After blow-down of the distribution piping. COPYRIGHT © 2025 BRAINBARTER ALL RIGHTS RESERVED 2 In those portions of systems intended to handle oxygen at pressure greater than 350 psi the inter connecting hose shall not contain what materials? A) brass. B) copper C) polymeric D) stainless steel - ANS C) Polymeric The tool shown here allows the installer to mechanically limit the makeup depth of the fitting to be brazed. Under what condition is this method permitted for the installation of medical gas piping? A) only on final line connectors. B) only on vacuum systems. C) where only B cup 5 brazing rod is used D) where the limited makeup depth is not less than minimum cut depth her ANSI / ASME recommendations - ANS D) Where the limited makeup depth is not less than minimum cup depth current ANSIASME recommendation What is the standard gauge pressure for nitrogen gas service? A) 15 - 30 B) 50 - 55 C) 162 185 D) it varies with system type. - ANS C) 50 - 55 psi What is a NFPA 99 requirement for labeling of pipes in medical gas system? A) color coding B) fixed label with C) label shall wrap completely around pipe. D) reflective label - ANS

Meer zien Lees minder
Instelling
NFPA
Vak
NFPA










Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
NFPA
Vak
NFPA

Documentinformatie

Geüpload op
21 juni 2025
Aantal pagina's
24
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

NFPA-99: PRACTICE TEST EXAM 2025
QUESTIONS AND ANSWERS


Under which of these conditions shall the instrument Air Reserve header cylinders be permitted
to be stored with the instrument air compressor?
A) the mechanical equipment room does not contain a boiler.
B) the medical air compressors are in the same room.
C) the only motor-driven machinery in the room is for instrument air equipment.

D) the room is secured with lockable doors. - ANS C) The only motor-driven machinery in the
room is for the instrument air equipment


Riser valves are those valves located where?
A) adjacent to the main riser downstream of any zone valve.
B) anywhere in the lateral branches of the piping system.
C) in the mainline adjacent to the base of the riser.

D) in the riser adjacent to the mainline. - ANS D) In the riser adjacent to the main line


When is the initial pressure test conducted by the installer?
A) after blowdown of the distribution piping.
B) after installation of alarm sensors.
C) before blowdown of distribution piping.

D) before installation of station rough in assembly. - ANS A) After blow-down of the
distribution piping.




COPYRIGHT © 2025 BRAINBARTER ALL RIGHTS RESERVED 1

,In those portions of systems intended to handle oxygen at pressure greater than 350 psi the
inter connecting hose shall not contain what materials?
A) brass.
B) copper
C) polymeric

D) stainless steel - ANS C) Polymeric


The tool shown here allows the installer to mechanically limit the makeup depth of the fitting
to be brazed. Under what condition is this method permitted for the installation of medical gas
piping?
A) only on final line connectors.
B) only on vacuum systems.
C) where only B cup 5 brazing rod is used
D) where the limited makeup depth is not less than minimum cut depth her ANSI / ASME
recommendations - ANS D) Where the limited makeup depth is not less than minimum cup
depth current ANSI\ASME recommendation


What is the standard gauge pressure for nitrogen gas service?
A) 15 - 30
B) 50 - 55
C) 162 185

D) it varies with system type. - ANS C) 50 - 55 psi


What is a NFPA 99 requirement for labeling of pipes in medical gas system?
A) color coding
B) fixed label with
C) label shall wrap completely around pipe.

D) reflective label - ANS A) Color coding


COPYRIGHT © 2025 BRAINBARTER ALL RIGHTS RESERVED 2

, A wireless communication device is employed in a medical gas or vacuum warning system. what
type of supervision is required for this device?
A) a visual indicator Shelby located in maintenance officer or engineering department.
B) this device shall be installed at the medical gas or vacuum source.
C) this device shall be located at nurses station.
D) this device will be supervised such that failure communication shall initiate an alarm. -
ANS D) This device will be supervised such that failure of communication shall initate an
alarm


In a facility where Medical Gas vacuum systems are present and the failure of such equipment
or systems is likely to cause any major injury or death to patients or caregivers this system shall
be designed to meet which category requirements?
A) 1
B) 2
C) 3

D) 4 - ANS A) category 1


A faculty is in the planning stages of installing an emergency oxygen service connection (ESOC).
How many feet is the minimum amount of clearance required around this connection?
A) 1 foot
B) 3 feet
C) 5 feet

D) Clearance must be 1-1/2 times the width of the auxiliary. - ANS B) 3 feet


Wooden rack for cylinder storage may be permitted under which conditions?
A) the wooden must be painted.
B) they are permitted with no set conditions .
C) they must be located in an area with fire suppression system.

D) Wooden racks are no longer permitted - ANS D) Wooden racks are no longer permitted

COPYRIGHT © 2025 BRAINBARTER ALL RIGHTS RESERVED 3

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Brainbarter Kaplan University
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
325
Lid sinds
2 jaar
Aantal volgers
153
Documenten
22254
Laatst verkocht
6 dagen geleden
A+ STUDY MATERIALS.

We offer a wide range of high-quality study materials, including study guides practice exams and flashcards. WELCOME.

3.5

54 beoordelingen

5
21
4
8
3
12
2
4
1
9

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen