What is the maximum drainer fixture units that a 4 inch trap arm can drain? - Answers 6
Trenches that are overexcavated and require backfilling below the level
of the pipe shall be backfilled in layers not exceeding: - Answers 6 inches
How many gallons of water are in 1 cubic foot? - Answers 7.5 gallons
Stell supports shall be protected against fire exposure with a fire resistance rating of at least ______
hours. - Answers 2
A combination plumbing fixture is permitted to be installed on one trap.
What is the requirement? - Answers One compartment is not more than 6 inches deeper than the other
compartments and the waste outlets are not more than 30 inches apart.
A building sewer shall have a cleanout: - Answers at intervals less than 100 feet
The international color code used by utility locators to mark an underground low voltage
communication line is. - Answers Orange
A fire sprinkler system connected to a potable water supply with a fire department connection shall be
protected against Backflow with: - Answers Double check valve or reduce pressure principle backflow
preventer
A gate valve is used for: - Answers On-off
What is the minimum number of fire sprinklers required for a 2900 sq. ft. single-story residence? -
Answers 8
How many threads may be cut on a one inch metallic pipe? - Answers 10
What would happen if you added a circulator with an expansion tank near the outlet side on a hydronic
boiler? - Answers It can cause cavitation
What is the minimum test duration for a gas supply line? - Answers 30 minutes
Gas piping (other than black or galvanized steel)run through bored holes in studs that are 7/8 of an inch
from the nearest edge shall be protected by a steel plate that extends how many inches to each side of a
stud, joist or rafter? - Answers 4 inches
The required size of the storm water drains and sewers for the roofs is
usually determined on the basis of the: - Answers effective roof area
How many laboratories required for a School that has 1100 boys in 1200 girls? - Answers 46
, Before a backhoe or grader can complete the backfill what minimum depth of clean fill is required over
the top of a sewer pipe? - Answers 12 inches
A church of 500 members, 250 which are men, shall have____
waterclosets for women. - Answers 6
Liquid level gauging devices shall be installed on containers filled by_____. - Answers Volume
A pressure regulator for a gas meter located inside of a building shall be ______. - Answers properly
vented
Thickness of aggregate material under a disposal pipe shall be a minimum of ____. - Answers 12 inches
Blue Stake uses orange to mark which of the following? - Answers Fiber optics, cable, telephone
When 140° temperature water or waste is to be discharged into a
drainage system ___. - Answers The pipes must be rated for the highest temperature
How close can a septic disposal line be to a 12 inch water main? - Answers 10 feet
What is required for materials that are used in medical gas piping systems? - Answers Delivered to job
site cleaned and capped
To ensure proper compactness around piping, trenches shall be backfilled with clean earth in 6 inch
layers to at least _____ inches above the top of the pipe; there after deeper layers are permitted. -
Answers 12
A vent pipe shall rise vertical to a point what minimum height above the
flood level rim of the fixture served before it can be offset horizontally? - Answers 6 inches
A tank that flushes more than one urinal: - Answers is prohibited
What minimum size septic tank is needed for a 5 bedroom house with
36 fixture units? - Answers 2000 gallon
What is the minimum nail plate thickness used to protect pipe in a wall? - Answers 16 gauge (0.0575)
A schedule 40 metallic pipe natural gas line supplies fuel for several
appliances which total 1530 cubic feet/hr. What size line is required by
code? Assume inlet pressure of less than 2.0 psi, maximum pressure
drop of 0.5 water column, specific gravity of 0.50, and the longest length