Created to serve as a complete, comprehensive code regulating the
construction of single-family, two-family and buildings consisting of three or
more townhouse units. - Correct Answer-IRC (International Residential
Code)
Administrative - Correct Answer-First 2 chapters of code book are
True - Correct Answer-Plans or supporting documents are almost always
required by the controlling authority prior to issuing a permit. T or F
Yes - Correct Answer-Does the building official have the authority to render
interpretations of the code?
8 foot fence. - Correct Answer-None of the following require a permit,
EXCEPT:
sidewalks and driveways
tiling
, Page |2
an 8 foot fence
playground equipment
False - Correct Answer-Tables and illustrations are always supported by
information found in the written code and footnotes. T or F
Live load. - Correct Answer-The amount of evenly distributed weight
imposed by inhabitants, goods and removable objects on a floor or roof
system is referred to as
True. - Correct Answer-If a code requirement is in the book, it is both
acceptable and enforceable by the code official. T or F
Figures. - Correct Answer-Illustrations are typically referred to as
Determine that buildings are built to the minimum enforceable standard. -
Correct Answer-Generally speaking, the building official's job is to
True. - Correct Answer-It is required that all manufacturer instructions be at
the jobsite at the time of inspection. T or F
, Page |3
Kitchen. - Correct Answer-All of the following are not considered habitable
spaces EXCEPT:
bathrooms
kitchens
storage spaces
closets
3. - Correct Answer-Bathrooms must be provided with an aggregate glazing
area no less than _____ square feet, half of which must be openable.
44 inches. - Correct Answer-The maximum height of an egress window
above the floor is
5.7 sq ft. - Correct Answer-A basement bedroom must have an egress
window with a clear opening of at least ______ square feet.
3. - Correct Answer-At least one side-hinged exit door must be in each
dwelling unit, and must be _____ feet wide.
30 inches. - Correct Answer-A porch more than _____ inches above grade
must be provided with 36" guards.
, Page |4
200. - Correct Answer-Wall and ceiling finishes shall have a flame-spread
classification of no more than ______ .
7 days. - Correct Answer-According to code, concrete must reach at least
70% of it's ability within ____________days.
40%. - Correct Answer-A stud used for a non-bearing partitions may not be
notched more than ____% of the stud width.
Additions, alterations, renovation and repairs. - Correct Answer-The
Michigan Uniform Energy code applies to new buildings as well as
U-factor. - Correct Answer-___________ is a measure of how well the
window or door assembly conducts heat. The lower the number, the better
insulation the assembly will provide.
50%. - Correct Answer-Energy losses from recessed lighting fixtures can
often reach ___% of the total thermal loss of a ceiling.