NICET Fire Alarm Level 1 UPDATED ACTUAL Exam Questions and CORRECT Answers When a device is inaccessible due to excessive height, such as an atrium, what it the maximum interval for testing? - CORRECT ANSWER - 18 months When installing a wall-mounted fire telephone appliance to the public, what is the acceptable maximum mounting height from the floor? - CORRECT ANSWER - 66 inches Elevator lobby smoke detectors shall be mounted within a maximum of which distance from the center-line of the door? - CORRECT ANSWER - 21 fe

Show more Read less
Institution
Nicet
Course
Nicet









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Nicet
Course
Nicet

Document information

Uploaded on
June 13, 2025
Number of pages
11
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

NICET Fire Alarm Level 1 UPDATED
ACTUAL Exam Questions and CORRECT
Answers
When a device is inaccessible due to excessive height, such as an atrium, what it the maximum
interval for testing? - CORRECT ANSWER - 18 months


When installing a wall-mounted fire telephone appliance to the public, what is the acceptable
maximum mounting height from the floor? - CORRECT ANSWER - 66 inches


Elevator lobby smoke detectors shall be mounted within a maximum of which distance from the
center-line of the door? - CORRECT ANSWER - 21 feet


At minimum, when working near power lines with voltage of 600 volts and lower, an aerial lift
operator shall maintain which distance from the lines? - CORRECT ANSWER - 10 feet


The use of unprotected EMT shall be permitted under which conditions? - CORRECT
ANSWER - when in direct contact with the earth


According to NFPA 70, what is the maximum unsupported length of 1/2-inch flexible metallic
conduit where flexibility is required after installation? - CORRECT ANSWER - 4 1/2 feet


What is the maximum bend (in degrees) permitted in a conduit run between outlet boxes? -
CORRECT ANSWER - 360 Degrees


If the primary power is disconnected and the fire alarm system goes into an alarm condition,
what is the minimum acceptable time for secondary power to operate the voice evacuation
systems? - CORRECT ANSWER - 15 minutes

, A riser room temperature switch should activate when the temperature falls below which level? -
CORRECT ANSWER - 40 degrees F


According to NFPA 72, what is the maximum sound pressure level permitted in a space with
notification appliances? - CORRECT ANSWER - 110 dBA


What is the minimum interval for testing a single-station smoke detector in multifamily units? -
CORRECT ANSWER - Annually


Where should a technician install a detector in relation to beam that is less than 12 inches deep
and less that 8 feet in center? - CORRECT ANSWER - At the bottom of the beam


An existing fire alarm cable in a drop ceiling will be spliced. which one of the following splice
locations will comply with NFPA 70? - CORRECT ANSWER - secured inside a listed box
or enclosure


Which function shall be tested for each newly installed smoke detector? - CORRECT
ANSWER - smoke entry?


An 180 foot long corridor is 10 feet wide, with a smooth 10 foot ceiling, interrupted by 4-inch
beams spaced every 10 feet. How many heat detectors with a listed 30 foot spacing are required?
- CORRECT ANSWER - 6 heat detectors


At which height must cables be physically protected when being installed within an exposed
ceiling? - CORRECT ANSWER - 7 feet


When shall smoke detectors be installed during the construction process? - CORRECT
ANSWER - After the final cleanup of all trades


Where structural members are provided, intermediate metal conduit shall be secured within
which maximum distance from an outlet box" - CORRECT ANSWER - 3 feet

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
MGRADES Stanford University
View profile
Follow You need to be logged in order to follow users or courses
Sold
1072
Member since
1 year
Number of followers
102
Documents
68976
Last sold
2 days ago
MGRADES (Stanford Top Brains)

Welcome to MGRADES Exams, practices and Study materials Just think of me as the plug you will refer to your friends Me and my team will always make sure you get the best value from the exams markets. I offer the best study and exam materials for a wide range of courses and units. Make your study sessions more efficient and effective. Dive in and discover all you need to excel in your academic journey!

3.8

170 reviews

5
73
4
30
3
45
2
8
1
14

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions