3.2.1* Approved. - ANSWER✔✔-Acceptable to the authority having jurisdiction.


3.2.2* Code. - ANSWER✔✔-A standard that is an extensive compilation of


provisions covering broad subject matter or that is suitable for adoption into law independently of

other codes and standards.


3.2.3* Guide. - ANSWER✔✔-A document that is advisory or informative in


nature and that contains only non-mandatory provisions. A guide may contain mandatory

statements such as when a guide can be used, but the document as a whole is not suitable for

adoption into law.


3.2.4* Recommended Practice. - ANSWER✔✔-A document that is similar in


content and structure to a code or standard but that contains only non-mandatory provisions using

the word "should" to indicate recommendations in the body of the text.


3.2.5* Standard. - ANSWER✔✔-An NFPA Standard, the main text of which




FOR STUDY PURPOSES ONLY COPYRIGHT © 2025 ALL RIGHTS RESERVED 1

,contains only mandatory provisions using the word "shall" to indicate requirements and that is in a

form generally suitable for mandatory reference by another standard or code or for adoption into

law. Non-mandatory provisions are not to be

considered a part of the requirements of a standard and shall be located in an appendix, annex,

footnote, informational note, or other means as permitted in the NFPA Manual of Style.

When used in a generic sense, such as in the phrase "standards development process" or "standards

development activities," the term "standards" includes all NFPA Standards, including

Codes, Standards, Recommended Practices, and Guides.


3.3.1* Absolute Temperature. - ANSWER✔✔-A temperature measured in Kelvins (K) or Rankines

(R).


3.3.2 Accelerant. - ANSWER✔✔-A fuel or oxidizer, often an ignitible liquid,


intentionally used to initiate a fire or increase the rate of growth or spread of fire.


3.3.3 Accident - ANSWER✔✔-An unplanned event that interrupts an activity and sometimes causes

injury or damage or a chance occurrence arising from unknown causes; an unexpected happening

due to carelessness, ignorance, and the like.


3.3.4 Active Fire Protection System. - ANSWER✔✔-A system that uses moving mechanical or

electrical parts to achieve a fire protection goal.


3.3.5 Ambient. - ANSWER✔✔-Someone's or something's surroundings, especially


as they pertain to the local environment; for example, ambient air and ambient temperature.


3.3.6 Ampacity. - ANSWER✔✔-The maximum current, in amperes, that a


FOR STUDY PURPOSES ONLY COPYRIGHT © 2025 ALL RIGHTS RESERVED 2

, conductor can carry continuously under the conditions of use without exceeding its temperature

rating. [70, Article 100]


3.3.7 Ampere. - ANSWER✔✔-The unit of electric current that is equivalent


to a flow of one coulomb per second; one coulomb is defined as 6.24 × 1018 electrons.


3.3.8 Arc. - ANSWER✔✔-A high-temperature luminous electric discharge


across a gap or through a medium such as charred insulation.


3.3.9 Arc Mapping. - ANSWER✔✔-The systematic evaluation of the electrical


circuit configuration, spatial relationship of the circuit components, and identification of electrical

arc sites to assist in the identification of the area of origin and analysis of the fire's spread.


3.3.10 Arc Site. - ANSWER✔✔-The location on a conductor with localized


damage that resulted from an electrical arc.


3.3.11 Arcing Through Char. - ANSWER✔✔-Arcing associated with a matrix


of charred material (e.g., charred conductor insulation) that acts as a semi-conductive medium.


3.3.12 Area of Origin. - ANSWER✔✔-A structure, part of a structure, or


general geographic location within a fire scene, in which the "point of origin" of a fire or explosion

is reasonably believed to be located. (See also 3.3.142, Point of Origin.)


3.3.13 Arrow Pattern. - ANSWER✔✔-A fire pattern displayed on the cross section


of a burned wooden structural member.




FOR STUDY PURPOSES ONLY COPYRIGHT © 2025 ALL RIGHTS RESERVED 3

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
KatelynWhitman West Virginia University
View profile
Follow You need to be logged in order to follow users or courses
Sold
1089
Member since
2 year
Number of followers
482
Documents
33020
Last sold
1 hour ago
Golden Quill Emporium Store

Get Yourself Well-Researched Study Materials to Ace Your Online& Actual Exam Tests with Confidence. STUDY LIKE A PRO WITH A WELL FORMATTED Q&A MATERIALS.

3.6

237 reviews

5
95
4
38
3
54
2
20
1
30

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can immediately select a different document that better matches what you need.

Pay how you prefer, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card or EFT and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions