Massachusetts Oil burner Exam Questions With Correct Answers 2025 Marking Scheme(A+ Pass) The cross connection between two supply tanks shall not exceed? - Answer - 660 gallons When is an automatic draft control not required? - Answer - When the equipment is designed to control the draft. Combustion performance testing can indicate: - Answer - Improper air oil mixture, too much combustion air, and low pump pressure. If a second oil-burning appliance is installed in a single chimney, you must insure: - Answer - Sufficient draft is available for safe operation of all connected equipment. Delayed ignition can be caused by: - Answer - Weak ignition transformer You should replace the oil burner nozzle with: - Answer - The manufacturers recommended nozzle spray pattern and spray angle. Viscosity problems can be corrected by: - Answer - Decreasing the nozzle size and increasing the pump pressure accordingly The minimum operating pressure of an oil pump is: - Answer - 100 PSI If a stack relay fails you, must? - Answer - Replace it with an approved type controller Aquastats are normally found on what type of heating systems? - Answer - Hydronic Airstats are found on what type of heating systems? - Answer - Forced warm air systems Under sized returns on a warm air system can result in what? - Answer - Short cycling of the oil burner Incorrect nozzle selection in regards to gallon per hour, can result in what problems in a steam system? - Answer - Some radiators not heating quickly enough Low boiler water temperature in a hydronic hot water system may be caused by? - Answer - Undersized oil burner nozzles Delayed opening oil valves are used to? - Answer - Allow oil pump to come up to speed If a steam boiler is to be installed with an automatic feeder it must also have: - Answer - A backflow prevention device How can a damaged heat exchanger be detected on a forced warm air system? - Answer - With a smoke trace candle If a high limit is installed to prevent high boiler water temperature, what is the function of the low limit? - Answer - To maintain temperature for domestic hot water

Meer zien Lees minder
Instelling
Massachusetts Oil Burner
Vak
Massachusetts Oil burner








Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Massachusetts Oil burner
Vak
Massachusetts Oil burner

Documentinformatie

Geüpload op
10 april 2025
Aantal pagina's
4
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

Massachusetts Oil burner Exam
Questions With Correct Answers 2025
Marking Scheme(A+ Pass)
The cross connection between two supply tanks shall not exceed? - Answer - ✔ 660
gallons

When is an automatic draft control not required? - Answer - ✔ When the equipment is
designed to control the draft.

Combustion performance testing can indicate: - Answer - ✔ Improper air oil mixture, too
much combustion air, and low pump pressure.

If a second oil-burning appliance is installed in a single chimney, you must insure: -
Answer - ✔ Sufficient draft is available for safe operation of all connected equipment.

Delayed ignition can be caused by: - Answer - ✔ Weak ignition transformer

You should replace the oil burner nozzle with: - Answer - ✔ The manufacturers
recommended nozzle spray pattern and spray angle.

Viscosity problems can be corrected by: - Answer - ✔ Decreasing the nozzle size and
increasing the pump pressure accordingly

The minimum operating pressure of an oil pump is: - Answer - ✔ 100 PSI

If a stack relay fails you, must? - Answer - ✔ Replace it with an approved type controller

Aquastats are normally found on what type of heating systems? - Answer - ✔ Hydronic

Airstats are found on what type of heating systems? - Answer - ✔ Forced warm air
systems

Under sized returns on a warm air system can result in what? - Answer - ✔ Short
cycling of the oil burner

Incorrect nozzle selection in regards to gallon per hour, can result in what problems in a
steam system? - Answer - ✔ Some radiators not heating quickly enough

Low boiler water temperature in a hydronic hot water system may be caused by? -
Answer - ✔ Undersized oil burner nozzles

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
BrightByte john hopkins university
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
46
Lid sinds
2 jaar
Aantal volgers
11
Documenten
3059
Laatst verkocht
1 maand geleden
BrightByte

BrightByte | Your #1 Source for Top-Tier Study Resources Struggling to keep up with your studies? Need high-quality notes to boost your grades? You’re in the right place! I’m BrightByte, a passionate and experienced study resource creator, dedicated to providing students with clear, concise, and exam-focused materials that make learning efficient and stress-free. Whether you’re prepping for an exam, revising key concepts, or just looking for well-structured study guides, my materials have got you covered! What You’ll Find Here: Premium Summaries – Well-organized, straight-to-the-point, and packed with essential information Exam-Focused Notes – Covering everything you need to know for top marks Lecture Notes & Study Guides – Comprehensive yet easy to digest Reliable & Well-Researched Content – Based on textbooks, lectures, and expert insights Subjects Covered: [List your key subjects, e.g., Business, Psychology, Law, Medicine, Engineering, etc.] Why waste hours filtering through irrelevant information? My notes help you study smarter, not harder. Explore my study materials now and take your academic success to the next level!

Lees meer Lees minder
3.0

3 beoordelingen

5
1
4
0
3
1
2
0
1
1

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Veelgestelde vragen