ELETRICIAN NCCER Which article of the NEC covers grounding? - Answer- Article 250 What is a dropout plate? - Answer- Metal plate with a curve surface for cable to follow as it passes from the tray All of the following are common service voltages in the United States Except: - Answer- 372/575 3-Phase, 4-wire What does a GFCI breaker do? - Answer- Opens a circuit to prevent operation of an electrical device What will happen when one or more coils in a winding are grounded? - Answer- The motor will automatically blow fuses eight incandescent lighting fixtures are to be installed. Each fixture is 120 volts, with a 200-whatt lamp what is the total connected load? - Answer- 13.3 Amps The __________must be grounded in a bussed glutter if use as the main service equipmemt - Answer- Neutral busbar When wall mounting cable tray, ensure that - Answer- The building structure is strong enough to support the tray system The purpose of sealing cable ends when reels of cable are in storage is ______________ - Answer- The outer covering on liquid-tight flexible metal conduit is use for - Answer- A moisture seal A good electrical connection should - Answer- Be mechanically and electrically secure The symbol normally use for duplex - Answer- Circle with two parallel lines draw through it Disconnecting means are covered in - Answer- NEC section 110-22 In relation to switches, the term throw refers to the - Answer- Number of internal operations that switch can perform A 3-phase, 4-wire, 480v service requires ________ current transformers - Answer- 3 Services conductors and equipment are covered in - Answer- NEC Article 230 The NEC required that all receptacles installed on 25 amp and 20 amp branch circuits be__________ receptacles - Answer- Grounding The circular mil is based on the - Answer- Cross-sectional area of the wire

Mehr anzeigen Weniger lesen
Hochschule
ELETRICIAN NCCER
Kurs
ELETRICIAN NCCER










Ups! Dein Dokument kann gerade nicht geladen werden. Versuch es erneut oder kontaktiere den Support.

Schule, Studium & Fach

Hochschule
ELETRICIAN NCCER
Kurs
ELETRICIAN NCCER

Dokument Information

Hochgeladen auf
3. april 2025
Anzahl der Seiten
19
geschrieben in
2024/2025
Typ
Prüfung
Enthält
Fragen & Antworten

Themen

Inhaltsvorschau

ELETRICIAN NCCER
Which article of the NEC covers grounding? - Answer- Article 250

What is a dropout plate? - Answer- Metal plate with a curve surface for cable to follow as it passes
from the tray

All of the following are common service voltages in the United States Except: - Answer- 372/575 3-
Phase, 4-wire

What does a GFCI breaker do? - Answer- Opens a circuit to prevent operation of an electrical
device

What will happen when one or more coils in a winding are grounded? - Answer- The motor will
automatically blow fuses

eight incandescent lighting fixtures are to be installed. Each fixture is 120 volts, with a 200-whatt
lamp what is the total connected load? - Answer- 13.3 Amps

The __________must be grounded in a bussed glutter if use as the main service equipmemt -
Answer- Neutral busbar

When wall mounting cable tray, ensure that - Answer- The building structure is strong enough to
support the tray system

The purpose of sealing cable ends when reels of cable are in storage is ______________ -
Answer- to keep moisture from creeping in

The outer covering on liquid-tight flexible metal conduit is use for - Answer- A moisture seal

A good electrical connection should - Answer- Be mechanically and electrically secure

The symbol normally use for duplex - Answer- Circle with two parallel lines draw through it

Disconnecting means are covered in - Answer- NEC section 110-22

In relation to switches, the term throw refers to the - Answer- Number of internal operations that
switch can perform

A 3-phase, 4-wire, 480v service requires ________ current transformers - Answer- 3

Services conductors and equipment are covered in - Answer- NEC Article 230

The NEC required that all receptacles installed on 25 amp and 20 amp branch circuits
be__________ receptacles - Answer- Grounding

The circular mil is based on the - Answer- Cross-sectional area of the wire

,A transformer with the primary of 400 turns and a secondary of 300 turns has a - Answer- Step
down turns ratio of 4:3

Of the termination classes listed below,_____ is the only one that provides a seal against external
elements - Answer- Class 1

Unless otherwise noted, the calculations in AC circuits ______ values - Answer- Rms

When the coil turns increased the ________ - Answer- Induced voltage is increased

As the temperature surrounding a self regulating heating cable rises, the ________ - Answer-
Resistance of the polymeric core increases

The motor type that has the highest starting torque is the _________ motor - Answer- Capacitor -
start

For a given number of poles, the________ determines the speed of an AC Motor. - Answer-
Frequency

Both induction and synchronous motor operate on the principle of the rotating________field -
Answer- Magnetic

A Transformer has 200 turns in the primary, 150 turns in the secondary, and 120VAC applied to
the primary. The voltage across the secondary is - Answer- 90 Volts

The output capacity of a motor is rated in - Answer- Horsepower

The synchronous speed at witcha 4 pole, 60 Hz induction motor operates is ________ rpm -
Answer- 1800

The sine of 0 degree is - Answer- 0

In a AC circuit containing resistance only, _______ 12A will flow if the resistance is 10 ohms and
the voltage is 120V - Answer- 12A

The _____ rotor types are generally rugged - Answer- Squirrel cage

The componente labeled 7 in figure 1 is a (an) - Answer- End seal

Meters used in AC circuits indicate the_______ - Answer- Effective

Proofs tests are made at________ oF the original factory voltage - Answer- 60%

Which type of heating cable can not be cut and terminated in the field? - Answer- Mineral insulated

The secondary of a CT under load should not be opened because of______ - Answer- Induced
hight voltage

In a transformer,______ - Answer- Electromagnetic induction occurs

, When a ground rod is installed, the top of the rod must be positioned _____.grade - Answer- Flush
with or below

When making offset bends, the two kicks must be made perfectly parallel or the resulting offset will
have a ________ - Answer- Crooked bend

All of the following types of condulet may be used as a pulling point for conduit that requires a 90
degree change in direction, except_______ - Answer- C

To be effective, a grounding system must limit the voltage on the electrical system and protect it
from all of the following, except ______ - Answer- Undervoltage conditions

What is the most common service use in a temporary power panel? - Answer- 120/240 volt, 1-
phase, 3-wire

What are the 2 most common types of overcurrent protective devices? - Answer- Circuit breakers
and fuses

What instrument is use to perform an insulation resistance test on a 480 volt motor winding? -
Answer- Megohmmeter

What is a seal installed in a run of conduit in a class I location? - Answer- Prevent the passage of
explosive gases in the conduit

Which of the following is the correct formula for OHM's law? - Answer- I=E/R

Which of the following testing instruments operated on the current transformer principle - Answer-
Clamp-on ammeter

A drowning showing a point A to point B hookup of conductors is called a - Answer- Wiring
diagram

What does HOA usually mean in a motor control circuit - Answer- Hands of automatic

A120/208 Volt feeder consist of an 800 ft run of 500 kcmil aluminum wire in conduit. This feeder
has 5% voltage drop. What will the phase-toPhase voltage be at the load end - Answer- 197.60
volts

What is voltage? - Answer- electromotive force

What is the standard wire size system used in the United States? - Answer- AWG

A switch labeled "AL-CU" can be use with what type of wire? - Answer- Aluminum Copper and
copper clad aluminum

What type of conduit fitting is usually placed in the middle of a long run of rigid metal conduit to
provide access for pulling wire - Answer- C

What is the largest size of aluminum rigid conduit couplings? - Answer- 6"

Lerne den Verkäufer kennen

Seller avatar
Bewertungen des Ansehens basieren auf der Anzahl der Dokumente, die ein Verkäufer gegen eine Gebühr verkauft hat, und den Bewertungen, die er für diese Dokumente erhalten hat. Es gibt drei Stufen: Bronze, Silber und Gold. Je besser das Ansehen eines Verkäufers ist, desto mehr kannst du dich auf die Qualität der Arbeiten verlassen.
Freshy Oxford University
Profil betrachten
Folgen Sie müssen sich einloggen, um Studenten oder Kursen zu folgen.
Verkauft
51
Mitglied seit
1 Jahren
Anzahl der Follower
4
Dokumente
6784
Zuletzt verkauft
6 Jahren vor

3.6

10 rezensionen

5
3
4
4
3
1
2
0
1
2

Kürzlich von dir angesehen.

Warum sich Studierende für Stuvia entscheiden

on Mitstudent*innen erstellt, durch Bewertungen verifiziert

Geschrieben von Student*innen, die bestanden haben und bewertet von anderen, die diese Studiendokumente verwendet haben.

Nicht zufrieden? Wähle ein anderes Dokument

Kein Problem! Du kannst direkt ein anderes Dokument wählen, das besser zu dem passt, was du suchst.

Bezahle wie du möchtest, fange sofort an zu lernen

Kein Abonnement, keine Verpflichtungen. Bezahle wie gewohnt per Kreditkarte oder Sofort und lade dein PDF-Dokument sofort herunter.

Student with book image

“Gekauft, heruntergeladen und bestanden. So einfach kann es sein.”

Alisha Student

Häufig gestellte Fragen