CORRECT ANSWERS 2025/2026
SetbackArequirementsA(WellsAandASprings)A-
AcorrectAanswersaAminAofA50'AfromAsepticAtankAandAminA100'AfromAabsorptionAfield
SetbackArequirementsA(PropertyAlines)A-
AcorrectAanswersaAminAofA10'AfromAsepticAtanks,AminAofA5'AfromAabsorptionAfieldsAforApropertyA
onApublicAwater
SetbackArequirementsA(bodiesAofAwaterAorAimpoundments)A-
AcorrectAanswersaAminAofA25'AfromAsepticAtanksAandAaAminAofA50'AfromAabsorptionAfields
SetbackArequirementsA(streamsAandAtributaries)A-
AcorrectAanswersaAminAofA25'AfromAsepticAtanksAandAaAminAofA50'AfromAabsorptionAfields
SetbackArequirementsA(pondedAwetlands)A-AcorrectAanswersaAminA50'AforAabsorptionAfields
SetbackArequirementsA(buildingsAwithAaAbasement)A-
AcorrectAanswersrequireAsepticAandAabsorptionAfieldsAminAofA10'
SetbackArequirementsA(buildingsAwithoutAaAbasement)A-
AcorrectAanswersrequireAanAabsorptionAfieldAplacementAaAminAofA5'AfromAtheAfoundation
SetbackArequirementsA(drainageAditch)A-
AcorrectAanswerssepticAtanksAmustAbeA15'AfromAdrainageAditch
absorptionAfieldsAminAofA15'AfromAtrashApitsAandAembankments
IfAtheAwaterAsupplyAlineAcrossesAorAcomesAwithinA10AfeetAofAtheAabsorptionAfield,A-
AcorrectAanswerstheAwaterAsupply
lineAshallAbeAinstalledAatAleastA12AinchesAaboveAtheAtopAofAtheAaggregateAlayerAofAtheAabsorpti
on
fieldAlineAandAshallAbeAencasedAinAsingle-lengthAlargerAdiameterAwaterApipe,AsuchAasA2"APVC
AllAsepticAtanks,Apre-castAorApouredAinAplace,A-AcorrectAanswerscontainAatAleastA2/3AofAthe
totalAliquidAcapacityAofAtheAtank
T/FASepticAtanksAmayAbeAconstructedAfromAmaterialAotherAthanAconcreteAwhenAapprovedAbyAt
he
departmentsAtechnicalAreviewAcommittee.A-AcorrectAanswersTrue
AAsepticAtankAforAone,Atwo,