Section
Well-blasted rock has a swell percentage of:
(Principles and Practices of Commercial Construction -->
Earthwork) correct answers20%
Lifelines in areas subjected to cutting or abrasion shall be a minimum of
inch wire core manila rope
(OSHA) correct answers7/8
All excavations made in Type B soil 20 feet or less in depth which have
vertically sided lower portions shall be shielded or supported to a height
inches above the top of the vertical side
(OSHA) correct answersAt least 18 inches
The calculated fire-resistance rating for a 3.8 inch thick sand and light
weight aggregate precast concrete wall shall be hour(s).
(Florida Building Code --> Calculated Fire Resistance) correct answers2
hours
Welded splices are almost always necessary in .
(Reinforcing Bars --> Welding) correct answersPrecast Concrete Construction
6.The OSHA area office has a maximum of days to assess the penalty
for failure to abate a violation.
(Florida Contractors Manual --> Categories of Violations) correct answers30
Days
7. High-density R-30 batts used in cathedral ceilings are inches thick.
(Energy Efficient Building Construction --> Cathedral Ceilings) correct
answers8 - 1/4
8.According to ASTM C94, when truck mixers are used the load must be
completely discharged within after batching.
(Design and Control of Concrete Mixtures --> Mixing Concrete) correct
answers90 Minutes
9.Floor landings in stairways shall be installed at intervals not to
exceed
. (Florida Building Code --> Stairway Construction, Landings) correct
answers12' Vertically
10.The thickness of concrete floor slabs supported directly on the
ground shall not be less than inches.
(Florida Building Code --> Concrete, Slab, Minimum) correct answers3 - 1/2
, 11.In , the tendons are raised higher above the forms in the
vicinity of the supporting column than at the midspan of the slab.
(Principles and Practices of Commercial Construction --> Tendon, Post
Tensioning)
correct answersPost-tensioned Concrete Slabs
12.The maximum permissible slope for access aisles serving
accessible parking spaces shall not be greater than .
(Accessibility) correct answers1:48
13.Excavations located five feet or less from the lot line during the
renovation of an existing building, shall be enclosed with a barrier not
less than feet high.
(Florida Building Code --> Barriers, Protection) correct answers6'
14.The preliminary site investigation is usually done .
(Principles and Practices of Commercial Construction --> Preliminary
Investigation) correct answersIn two stages
15.Where permitted, spiral stairways shall be constructed in such a way
that the risers shall be sufficient to provide a headroom of minimum.
(Florida Building Code --> Spiral Stairs, Construction) correct answers6' - 6"
16.Whenever materials are dropped to any point outside the exterior
walls of the building, an enclosed chute shall be used.
(OSHA --> Chutes) correct answersMore than 20'
17.Automatic sprinkler systems in residential structures up to and
including four stories in height shall be permitted to be installed in
accordance with .
(Florida Building Code --> Automatic Sprinkler Systems) correct
answersNFPA 13-47R
18.Masonry cements consist of portland cement together with
other materials to enhance all of the following except .
(Design and Control of Concrete Mixtures --> Masonry Cement) correct
answersAir- Entrainment
19.In steel frame construction, cross-bracing loads are typically .
(Principles and Practices of Commercial Construction --> Cross Bracing,
Structural Steel) correct answersIn Tension
20.Barricades for protection of employees shall conform to .
(OSHA --> Barricades) correct answersThe Manual on Uniform Traffic
Control Devices
21.The minimum dimensions for a crawl space access opening in a
building shall be not less than inches.
(Florida Building Code --> Crawl Space, Access) correct answers18" x 24"