100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

Internachi Florida State Exam with 100% correct answers 2025

Beoordeling
-
Verkocht
-
Pagina's
33
Cijfer
A+
Geüpload op
26-03-2025
Geschreven in
2024/2025

The typical electrical service for homes in North America is a_____? correct answers120240 Volt The 240 Volt circuit is used for? correct answersAppliances The return conductor (a.k.a. the neutral) is at ___ volts because it is grounded to the electric panel correct answersZero Most 120 Volt circuits are wired to deliver ___ or ___ Amps of current correct answers15, 20 Most ___ Buildings are supplied with 120240 Volt services. This means that the cable assembly is made up of ___ ungrounded conductors each supplying 120 V with one ground correct answersResidential, two The point of attachment of the service drop conductors to a building or structure must have a clearance of at least ___ ft correct answers10 Vertical clearance for overhead conductors they are over public streets correct answers18 feet Vertical clearance for overhead conductors that are over commercial parking areas correct answers18 feet Vertical clearance for overhead conductors that are over swimming pools? correct answers22 feet and 6 inches, 10 feet horizontal Vertical clearance for overhead conductors that are over residential properties? correct answers12 feet Vertical clearance for overhead conductors that are from sides of doors? correct answers3 feet from the bottom, sides and front The inspector should recommend that any ____ Within 5 to 6 feet be cut back correct answersTree limbs The clearance for open overhead service conductors from the front, bottom and sides of windows that______Is 3 feet correct answersOpen Every 5 to 6 feet, rigid service mast should be secured to ___ correct answersThe structure points

Meer zien Lees minder
Instelling
Internachi Florida State Exa
Vak
Internachi Florida State Exa











Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Internachi Florida State Exa
Vak
Internachi Florida State Exa

Documentinformatie

Geüpload op
26 maart 2025
Aantal pagina's
33
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

Internachi Florida State Exam

The typical electrical service for homes in North America is a
? correct answers120\240 Volt

The 240 Volt circuit is used for? correct answersAppliances

The return conductor (a.k.a. the neutral) is at volts because it is
grounded to the electric panel correct answersZero

Most 120 Volt circuits are wired to deliver or Amps of
current correct answers15, 20

Most Buildings are supplied with 120\240 Volt services. This means that
the cable assembly is made up of ungrounded conductors each supplying
120 V with one ground correct answersResidential, two

The point of attachment of the service drop conductors to a building or
structure must have a clearance of at least ft correct answers10

Vertical clearance for overhead conductors they are over public
streets correct answers18 feet

Vertical clearance for overhead conductors that are over commercial
parking areas correct answers18 feet

Vertical clearance for overhead conductors that are over swimming
pools? correct answers22 feet and 6 inches, 10 feet horizontal

Vertical clearance for overhead conductors that are over residential
properties? correct answers12 feet

Vertical clearance for overhead conductors that are from sides of
doors? correct answers3 feet from the bottom, sides and front

The inspector should recommend that any Within 5 to 6 feet be cut
back correct answersTree limbs

The clearance for open overhead service conductors from the front, bottom
and sides of windows that Is 3 feet correct answersOpen

Every 5 to 6 feet, rigid service mast should be secured to correct
answersThe structure points

,The method for installing a UF cable is correct answersAbove ground

A service entrance with Connected conductors is a phase 3 supply
correct answersFour

The typical supply for square brand electric meter is amps correct

answers100 Most modern 200 amp electrical meters are marked correct

answers200 CL

The minimum conductor size for a Amp service is a 4 AWG copper or 2
AWG aluminum correct answers100

Is a direct connection to the earth to aid in removing damaging
transient over voltages due to lightning correct answersGrounding

Need to be bonded to the ground correct answersAll panel enclosures

Conductors between the main service disconnect to the distribution

panels are called
correct answersFeeders

How can you bonded a remote distribution panel? correct answersBy
connecting the enclosure to the grounding bus

100 Amps is the Service required for a new single-family home
correct answersMinimum

The electrical supply should be shut down with movements of the hand
correct answersSix or fewer

A common cause of arc flashes when removing panel fronts is ?
correct answersIncorrect fasteners

A split bus electrical panel uses a double pole breaker to The120 V
circuits correct answersIsolate

Which of the following would NOT be a defect? correct answersWire splices

Electrical service panel should be in a clear space measuring ?
correct answers30 inches wide by 78 inches high by 36 inches deep

Fused main disconnects are usually a maximum of amps correct

answers100 Upgrading to fuses stops over

fusing correct answersS

,Electric panel buses colored red, blue, and black are indicative of a
?
correct answersThree phase supply

GFCI breakers have conductors correct answersTwo

What wiring would require a specialist? correct answersSolid conductor
aluminum branch wiring

Or horizontally mounted face up countertop receptacles allowed? correct

answersNo The first kind of residential wiring is called? correct

answersKnob and tube

"Romex " cable that is not actually of the brand romex is called? correct
answersType NM cable

What circuit should bathroom outlets be on? correct answers20

amp GFCI What is the minimum circuit for stoves? correct

answers40 amp

How many amps is an electrical clothes dryer? correct
answers30 Amp

Recessed ceiling lights should be rated if installed against insulation.
correct answersIC

In a typical residential air-conditioning system, the Absorbs the heat
energy from the air passing through it, and transfers heat from the passing
air to the refrigerant moving inside correct answersEvaporator

The Is located inside the outdoor condenser unit and receives the low
pressure refrigerant vapor through the suction line correct
answersCompressor

The maximum discharge temperature for ducts of a warm air heating
system is F
correct answers250

A is a device used to alter the volume of air passing through a
confined cross section by changing the size of the cross section area
correct answersDamper

T/F: You are required to inspect the insulation in unfinished spaces,
including the attic correct answersTrue

T/F: you are required to inform your client about the absence or lack of
adequate insulation in areas of the house correct answersTrue

Water vapor can move in three ways transportation, diffusion
through materials,
diffusion correct answersAir, thermal

, Movement accounts for more than 98% of all water vapor movement
and building cavities correct answersAir

diffusion is how moisture in a vapor state moves through material
because of a difference in pressure or difference in temperature correct
answersVapor

Diffusion is water vapor moving through a material from a high
pressure to a low pressure or from a warm side of the wall to a cool side
correct answersVapor

Refers to the amount of moisture contained in a quantity of air compared
to the maximum amount of moisture in the air that could hold at the same
temperature correct answersRelative humidity (RH)

4 general things you can do to prevent moisture intrusion is
1. Prevent water intrusion
2.
3. air leaks
4. Provide an escape for moisture correct answersVentilate, stop

Typically a thin metal strip found around the door correct
answersFlashing

Be sure to communicate to your clients that your inspection is a ,
inspection of the readily accessible components of the house correct
answersVisual, non-invasive

Insulations resistance to heat flow is measured or rated in terms of
its thermal resistance, a.k.a. correct answersR-value

Insulation in between studs in a wall does not restrict the heat flow through
those studs. This heat flow is called ? correct answersThermal bridging

cups of water enter through a "1/2 inch round hole via air
transportation in a year" correct answers5

And 100 square ft wall, Of water can diffuse through drywall without
a vapor diffusion retarder in a year correct answers1 cup

If ducts of the HVAC system run through uncondition spaces in the house,
such as a crawlspace or attic, then the ductwork should be correct
answersInsulated

In general, -cell foams allow water to move through the wall more
easily then
-cell foams correct answersOpen, closed

Of attic areas is intended to prevent the accumulation of moisture vapor
in the attic correct answersVentilation

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
HopeJewels Chamberlain College Of Nursing
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
70
Lid sinds
1 jaar
Aantal volgers
10
Documenten
8694
Laatst verkocht
1 week geleden
macellen education agencies

On this page, you find all documents,testsbank ,solution manuals, package deals, On this page, you find all documents, package deals, and flashcards offered by seller Hopejewels

3.2

5 beoordelingen

5
2
4
0
3
1
2
1
1
1

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen