100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

LA Steam Engineer EXAM Questions and Answers with complete solution2025(Graded A+)

Beoordeling
-
Verkocht
1
Pagina's
26
Cijfer
A+
Geüpload op
25-03-2025
Geschreven in
2024/2025

LA Steam Engineer EXAM Questions and Answers with complete solution2025(Graded A+)

Instelling
LA Steam Engineer E
Vak
LA Steam Engineer E










Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
LA Steam Engineer E
Vak
LA Steam Engineer E

Documentinformatie

Geüpload op
25 maart 2025
Aantal pagina's
26
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

LA Steam Engineer EXAM Questions and
Answers with complete solution2025(Graded
A+)

A desuperheater that is installed in a boiler is used to control.. - CORRECT ANSWERS
Super heated steam temperature

Economizers are finned to.. - CORRECT ANSWERS Increase the rate of heat
for heat transfer

The heat transfer taking place in a surface condenser is accomplished mainly by.. -
CORRECT ANSWERS Conduction

An unfired pressure vessel which is used to transfer heat from one substance to another
is called.. - CORRECT ANSWERS Feed water heater, Evaporator and Oil Cooler

Boiler economizers are primarily used for.. - CORRECT ANSWERS Recovery
heat from flue gas

The main purpose of the deaerator is to.. - CORRECT ANSWERS Eliminate
non-condensable gases

Superheated steam is more efficient because.. - CORRECT ANSWERS
Temperature & Total heat content are increased

A spear boiler feed water pump is equipped with a check valve in the discharge line to...
- CORRECT ANSWERS Permit fast start up by leaving the discharge valve open

Excessive fireside deposits on heating surfaces of a uncontrolled super heated boiler
would be indicated by... - CORRECT ANSWERS Decreased super heater outlet
temperature

Why is the super heater safety valve set to release before the drum safety? -
CORRECT ANSWERS To ensure flow through the super heater

What is the purpose of a steam trap? - CORRECT ANSWERS To drain water
and air

A steam trap utilizes flash steam to open but what comes after for the closing
operation? - CORRECT ANSWERS Impulse

,Pitting in suction areas of a bronze impeller in centrifugal pumps is usually caused by? -
CORRECT ANSWERS (Best answer) Cavitation or (Second Best) Corrosion

What type of pump has no moving parts? - CORRECT ANSWERS Jet pump

Centrifugal boiler feed water pumps are usually equipped with? - CORRECT
ANSWERS Bypass valves

Which condition is the probable cause of centrifugal pump failure to deliver water when
first started? - CORRECT ANSWERS Pump is not primed

Low pressure from metering or proportioning pumps may be caused by? - CORRECT
ANSWERS Rapid wear on plunger

If a centrifugal pump that operates with suction lift becomes air bound you should? -
CORRECT ANSWERS Reprime the pump

An important consideration in the prevention of carryover in a boiler is to? - CORRECT
ANSWERS Control water level

As alkalinity of boiler water increases the water inside the boiler becomes increasingly
_________? - CORRECT ANSWERS Soft

The residue created from chemically treated feed water remains in the boiler thus
increasing the need for? - CORRECT ANSWERS Boiler Blowdown

Grooving and pitting is caused by? - CORRECT ANSWERS Dissolved O2 and
CO2

What test is used to detect corrosive boiler water? - CORRECT ANSWERS
Hardness Test

Chemical which would not be used for the purpose of regeneration of softner and
dematerialize is? - CORRECT ANSWERS Sulfuric acid

Why are continuous blow downs necessary on high make up? - CORRECT ANSWERS
To maintain proper dissolved boiler water solids

Steam seperation is less effective when there is? - CORRECT ANSWERS High
water level in the drum

Soft sludge in the waterside of the boiler can be readily produced by? - CORRECT
ANSWERS Dissolved salts

, Oxygen entrapped in feed water entering the boiler can cause? - CORRECT
ANSWERS Erosion

Non condensable gases and O2 are removed from boiler feed water by? - CORRECT
ANSWERS Dearation

The limitation placed upon acceptable solids in boiler feed water is? - CORRECT
ANSWERS (Not 100% sure) There is no "acceptable" limit

The use of pre heated combustion air increases ____________. - CORRECT
ANSWERS Efficiency

To minimize boiler damage if a water wall tube suddenly fails you should continue feed
water supply and immediately ____________________. - CORRECT ANSWERS
Reduce firing rate of boiler

Boiler water pH should be in what range? - CORRECT ANSWERS 9.0 - 11.0

When air or products of combustion are caused to flow to or through a unit by
maintaining them at pressure above atmospheric the draft system is said to be under
what kind of draft? - CORRECT ANSWERS Force Draft

Air from a boiler fan may be controlled by? - CORRECT ANSWERS Outlet
vanes, inlet vanes and damper

The advantage of a steam atomizing oil burner is that it uses
_________________________. - CORRECT ANSWERS Oil of any viscosity

Furnace refractory spalling in boilers equipped with mechanical fuel atomizers is caused
by thermal shock from what? - CORRECT ANSWERS Rapid uneven heating

A pulsating effect in the furnace of an oil fired boiler could be caused by? - CORRECT
ANSWERS Insufficient combustion air supply

The burner assembly sprayer plate controls the ________________. - CORRECT
ANSWERS Flow of the fuel in the whirling chamber

The primary air flow through the burner register provides air necessary for
_____________. - CORRECT ANSWERS Sustained combustion in the furnace

The boiler superheater raises the temperature of the _________. - CORRECT
ANSWERS Steam leaving the boiler

When the boiler firing rate increases, combustion control does what? - CORRECT
ANSWERS Increases the air first, followed by the fuel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
NURSINGGRADER2012 California Southern University
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
191
Lid sinds
4 jaar
Aantal volgers
166
Documenten
5260
Laatst verkocht
3 weken geleden
ALEVEL-HELP FOR ALL NURSING STUDENTS GRADING A+

NURSING COURSE IS SO HARD, GET ITS SOLUTION FROM VARIOUS DOCUMENTS THAT WILL ENABLE NURSING COURSE TO BE EASIER IN ALL FEILDS.THE PLATFORM IS PERTAINING ALL DOCUMENTS CONCERNING NURSING.

3.7

31 beoordelingen

5
15
4
4
3
3
2
5
1
4

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen