LP INSTALLERS PRACTICE EXAM QUESTIONS AND
ANSWERS
Where do you file a permit for work to be done in buildings owned or used by the State
of Mass ? - Answers :State Inspector

When pressure testing a system over 1 million btu , which doesn't apply ? - Answers
:Test 1 hour for each 200 ' of developed length

When a vent on a regulator , what is the horizontal distance from the discharge of the
vent to an opening located below ? - Answers :3 feet

How many cycles do you need to keep continuing education certificates ? - Answers :3

On an LP - Gas system , what is considered to be the " Point of Delivery " ? - Answers
:Outlet of 1st stage

How fast does a spill switch need to work ? - Answers :30 seconds

If the firing rate in a combustion chamber exceeds 1,000,000 BTU , but less than
5,000,000 , what is required ? - Answers :2 shut offs in series , or one with overtravel
interlock

What is the maximum pressure allowed for CSST . - Answers :14 " WC

If the maximum firing rate per combustion chamber is ____ , BTU or greater , gas
pressure supervision provided by listed pressure switches or combination high / low
switch , interlocked to accomplish safety shutdown in event of either high or low
pressure . - Answers :1,000,000

Max spacing for support for CSST on a rooftop is every . - Answers :Blocks used for
Support 48 "

A vacuum is considered to be any pressure that is - Answers :Less than atmospheric
pressure (14.7 psi)

If an UG gas line runs under a building , what is required ? - Answers :Conduit must
terminate outside building ,Sleeved in same material as pipe Terminate 4 ' above grade

Apprentice plumber , apprentice gas fitter , or MA Lic . LP Installer - Answers :Must
show license when asked by the Inspector

What is not an acceptable material for LPG piping - Answers :Butylenes

, How far above a forced air inlet must a vent be terminated it within 10 ft horizontally ? -
Answers :3 '

Can you vent into a mechanical vent under a positive pressure ? - Answers :no

What is not an acceptable material for LPG piping ? - Answers :Galvanized

How far above the floor must you have an opening for make - up air ? - Answers :< 12 "

How far can a relief discharge from a rigid LP gas regulator from a Building Opening
below discharge ? - Answers :3'

Which method is not an approved method of connecting pipe ? - Answers :Soldered

When using gas pressure boosters , which of the following apply ? - Answers :All must
meet product - acceptance requirements The serving gas supplier has provided written
authorization Gas pressure boosters shall be located in well - ventilated spaces , and
readily accessible

What percentage of vent height can the length of a single - walled vent connector be ? -
Answers :75 %

What percentage of vent height can the length of Type B , double - walled vent
connector be ? - Answers :100 %

What is the max pressure for natural gas in a house ? - Answers :14 " WC

Within how many feet of an appliance does the shut off need to be ? - Answers :6'

How far does a roof hatch need to be from the edge of a roof to not need guardrails ? -
Answers :6'

Vent termination above a public walkway needs to terminate how high above grade ? -
Answers :7 '

Decorative gas appliance in a vented fireplace must have ? - Answers :Screen door

When opening / adding to a gas system who must be notified prior to commencing work
? - Answers :Local Inspector

When there is suspicion of a defect in the piping system , you must ____ - Answers
:Perform test on system ✓

Installation of fuel gas utilization equipment over BTUs / hr per combustion chamber
shall be governed by 248 CMR 7.00 : Large Gas Utilization Equipment . - Answers
:400,000

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Greaterheights Birkbeck, University of London
View profile
Follow You need to be logged in order to follow users or courses
Sold
1126
Member since
3 year
Number of followers
880
Documents
18641
Last sold
1 day ago

4.1

218 reviews

5
120
4
43
3
24
2
10
1
21

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions