100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

IDPX Exam simply well answered

Rating
-
Sold
-
Pages
13
Grade
A+
Uploaded on
15-03-2025
Written in
2024/2025

IDPX Exam simply well answered dead load - ANSWERSWeight (lbs/per sq ft.) of actual building materials (the weight of the structure itself); static, fixed loads (bldg, structure, skin, fixed equipment); includes columns, beams, exterior & interior walls, floors, and mechanical equipment. minimum clear floor space required for a wheelchair - ANSWERS30"x48" typical riser height - ANSWERS7" most common metal wall stud depth - ANSWERS2 1/2" The maximum glazed area cannot exceed what percentage of the area of the corridor wall of the room separating it from the corridor - ANSWERS25% not to exceed 1296 square inches Vertical members used between double doors to seal the opening and provide extra security when the doors are closed - ANSWERSastragals ADA ramp ratio of rise to run - ANSWERS1:12 In arranging exits in a space, what should be the minimum distance between means of egress - ANSWERShalf the distance of the diagonal of the building area maximum grab bar height in a barrier-free commercial restroom - ANSWERS36" minimum clear width of a 6' long hallway - ANSWERS36" (occupant load less than 50), 44" (occupant load more than 50) types of windows that meet life safety standards - ANSWERSdouble-hung, sliding, casement used to test furniture upholstery - ANSWERSsmolder resistance test, steiner tunnel test, smoke density test minimum dimension for the bottom handrail extension on a stair handrail - ANSWERSnot less than the depth of one tread beyond the bottom riser diameter of stair handrail - ANSWERSbetween 1.25"-2" Most federal agencies require a smoke density rate of - ANSWERS450 or less

Show more Read less
Institution
IDPX Imply Well Answered Dead Load - ANSWER
Course
IDPX imply well answered dead load - ANSWER

Content preview

IDPX Exam simply well answered
dead load - ANSWERSWeight (lbs/per sq ft.) of actual building materials (the weight of
the structure itself);
static, fixed loads (bldg, structure, skin, fixed equipment); includes columns, beams,
exterior & interior walls, floors, and mechanical equipment.

minimum clear floor space required for a wheelchair - ANSWERS30"x48"

typical riser height - ANSWERS7"

most common metal wall stud depth - ANSWERS2 1/2"

The maximum
glazed area cannot exceed what percentage of the area of the corridor wall of the room
separating it
from the corridor - ANSWERS25% not to exceed 1296 square inches

Vertical members used between double doors to seal the opening and provide extra
security
when the doors are closed - ANSWERSastragals

In arranging exits in a space, what should be the minimum distance between means of
egress - ANSWERShalf the distance of the diagonal of the building area

ADA ramp ratio of rise to run - ANSWERS1:12

maximum grab bar height in a barrier-free commercial restroom - ANSWERS36"

minimum clear width of a 6' long hallway - ANSWERS36" (occupant load less than 50),
44" (occupant load more than 50)

types of windows that meet life safety standards - ANSWERSdouble-hung, sliding,
casement

used to test furniture upholstery - ANSWERSsmolder resistance test, steiner tunnel
test, smoke density test

minimum dimension for the bottom handrail extension on a stair handrail -
ANSWERSnot less than the depth of one tread beyond the bottom riser

diameter of stair handrail - ANSWERSbetween 1.25"-2"

Most federal agencies require a smoke density rate of - ANSWERS450 or less

, Window treatments in office buildings - ANSWERSmust meet NFPA 701 (vertical
ignition test)

Which of the following labels is required by code for a 20-minute-rated wooden door -
ANSWERSUL (underwriters laboratory)

Interior wall and ceiling textile finishes are classified in accordance with which IBC
specific testing
method or standard - ANSWERSASTM E-84 (Steiner Tunnel Test - Flame spread rating
of finishes)

amount of clear space to be maintained below a sign or other ceiling projection -
ANSWERS80"

What is the percentage of wall and ceiling area that the trim
cannot exceed? - ANSWERS10%

In a plenum, how can a fire be prevented from spreading horizontally - ANSWERSuse
fire-rated dividers (it is usually an extension of a fire-rated partition.)

Sound travels by - ANSWERSfrequency ( # of cycles per second; measured in hertz)

The principal consideration in acoustic control is the sound absorptive quality of the -
ANSWERSActually, in large rooms the ceiling treatment is most effective. In smaller
rooms, the
wall treatment is more effective.

STC rating is used to provide an evaluation of the space in terms of -
ANSWERSacoustical quality ( Sound Transmission Class; used to rate the transmission
loss of construction. The higher the STC rating, the better the barrier is at stopping
sound.)

wall assembly with a fire-resistance rating of 1 hour (demising walls) - ANSWERSfire
partition

minimum width of stair tread - ANSWERS11"

IBC Occupancy Classification - ANSWERSA - Assembly (civic, social, or religious
functions; recreation, food, or drink consumption; awaiting
transportation; production & viewing of performing arts or motion pictures; sporting
events)
B - Business (office, professional, or service-type transactions)
E - Educational (through 12th grade; including daycare)
F - Factory / Industrial (assembling, fabricating, manufacturing, packaging, repair, or
processing)

Written for

Institution
IDPX imply well answered dead load - ANSWER
Course
IDPX imply well answered dead load - ANSWER

Document information

Uploaded on
March 15, 2025
Number of pages
13
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$10.99
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
muchiracalorine

Get to know the seller

Seller avatar
muchiracalorine waldern university
View profile
Follow You need to be logged in order to follow users or courses
Sold
2
Member since
2 year
Number of followers
1
Documents
137
Last sold
11 months ago

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions