Answers 100% Pass
Burning one cubic foot of natural gas will produce approximately _____
BTU's - ✔✔900-1,100 BTU
The Natural Fuel Gas code classifies a vent system for a condensing
furnace as : - ✔✔Category IV
what type of draft is used to move flue gas through the heat exchanger and
into the venting system in modern gas-fired furnaces? - ✔✔Mechanical
A customer complains that a 2-year-old, direct, hot surface ignition furnace
will not light. The inducer motor runs, the pressure switch closes, and the
igniter begins to glow, but there is no ignition. The furnace locks out while
attempting to light. After resetting the furnace, 17 VAC is measured at the
1
100% Pass Guarantee Katelyn Whitman, All Rights
, gas valve and the technician correctly concludes: - ✔✔The Electonic board
is faulty
The efficiency rating of gas-burning appliance is determined using: -
✔✔Annual Fuel Utilization Efficiency (AFUE)
when the burners of a furnace are ignited the blower motor operation is
delayed to: - ✔✔Allow heat exchanger to warm up
Typical condensing furnaces have an AFUE rating of at least - ✔✔90%
A gas furnace has an integrated furnace control (IFC). How is the fan
cycled during heating? - ✔✔Heat Relay
What reading should a good thermocouple produce on a DC meter - ✔✔30
millivolts
A furnace nameplate specifies a temperature rise of 40 to 70 degrees.
Temperature measurements indicate a rise of 80 degrees. The most
appropriate action is to: - ✔✔Increase the fan speed
The most common burner used in induced draft furnace is: - ✔✔In-shot
2