100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

HVAC Excellence - Heat Pump - Weeks 1 and 2 – COMBINED Questions and Answers 100% Pass

Rating
-
Sold
-
Pages
8
Grade
A+
Uploaded on
10-03-2025
Written in
2024/2025

HVAC Excellence - Heat Pump - Weeks 1 and 2 – COMBINED Questions and Answers 100% Pass An air-to-air heat pump has many of the same components as an air conditioning system. The major difference is that a heat pump also has a/an - Reversing valve What is the difference between "demand defrost" and "timed defrost"? - Demand defrost happens only when needed and timed defrost is based on time/temperature. The thermostat that controls the auxiliary electric heat according to the outdoor temperature is called the _____________________. - Outdoor ambient thermostat 2 100% Pass Guarantee Katelyn Whitman, All Rights The outdoor temperature at which the heat pump provides the same amount of heat as the heat loss of the conditioned space without an auxiliary heat is known as the __________________. - Initial balance point At what temperature is an outdoor ambient thermostat normally set? - Slightly above the initial balance point. The outdoor coil is frozen solid on a "no heat" service call. The most likely reason is ________________________. - The outdoor fan is inoperative. In order to determine a heat pumps' balance point, you must first calculate __________________________. - The building's heat load. When a heat pump is used for heating and cooling, the system is sized by the ___________________________. - Cooling load. A high efficiency heat pump system, designed to function from high to low ambient conditions below 10*F, may have _____________________. - an auxiliary heat exchanger injected with ethylene glycol solution. 3 100% Pass Guarantee Katelyn Whitman, All Rights Room thermostats for heat pumps should be installed ___________________. - As near to the main return air grill as possible. When the heat pump compressor has malfunctioned, the customer has the option to switch the system into _______________________________. - Emergency heat mode. Start up with a night set back digital thermostat requires the technician to always __________________________. - Teach the customer how to program the thermostat. The heat pump defrost board can be manipulated by the technician to ___________________________. - Simulate the defrost cycle. The air-to-air heat pump outdoor unit is most efficient if located ____________________________. - In a moderate climate zo

Show more Read less
Institution
Hvac
Course
Hvac









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Hvac
Course
Hvac

Document information

Uploaded on
March 10, 2025
Number of pages
8
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

HVAC Excellence - Heat Pump - Weeks
1 and 2 – COMBINED Questions and
Answers 100% Pass


An air-to-air heat pump has many of the same components as an air

conditioning system. The major difference is that a heat pump also has

a/an - ✔✔Reversing valve


What is the difference between "demand defrost" and "timed defrost"? -

✔✔Demand defrost happens only when needed and timed defrost is based

on time/temperature.


The thermostat that controls the auxiliary electric heat according to the

outdoor temperature is called the _____________________. - ✔✔Outdoor

ambient thermostat




1
100% Pass Guarantee Katelyn Whitman, All Rights

, The outdoor temperature at which the heat pump provides the same

amount of heat as the heat loss of the conditioned space without an

auxiliary heat is known as the __________________. - ✔✔Initial balance

point


At what temperature is an outdoor ambient thermostat normally set? -

✔✔Slightly above the initial balance point.


The outdoor coil is frozen solid on a "no heat" service call. The most likely

reason is ________________________. - ✔✔The outdoor fan is inoperative.


In order to determine a heat pumps' balance point, you must first calculate

__________________________. - ✔✔The building's heat load.


When a heat pump is used for heating and cooling, the system is sized by

the ___________________________. - ✔✔Cooling load.


A high efficiency heat pump system, designed to function from high to low

ambient conditions below 10*F, may have _____________________. - ✔✔an

auxiliary heat exchanger injected with ethylene glycol solution.




2
100% Pass Guarantee Katelyn Whitman, All Rights

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
KatelynWhitman West Virginia University
View profile
Follow You need to be logged in order to follow users or courses
Sold
1095
Member since
2 year
Number of followers
482
Documents
33057
Last sold
1 day ago
Golden Quill Emporium Store

Get Yourself Well-Researched Study Materials to Ace Your Online& Actual Exam Tests with Confidence. STUDY LIKE A PRO WITH A WELL FORMATTED Q&A MATERIALS.

3.6

238 reviews

5
95
4
38
3
54
2
20
1
31

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions