©FYNDLAY 2024/2025 ALL RIGHTS RESERVED 8:10PM. 1 Massachusetts Oil burner Practice Exam Questions And Answers 2025 Update. The cross connection between two supply tanks shall not exceed? - Answer660 gallons When is an automatic draft control not required? - AnswerWhen the equipment is designed to control the draft. Combustion performance testing can indicate: - AnswerImproper air oil mixture, too much combustion air, and low pump pressure. If a second oil-burning appliance is installed in a single chimney, you must insure: - AnswerSufficient draft is available for safe operation of all connected equipment. Delayed ignition can be caused by: - AnswerWeak ignition transformer You should replace the oil burner nozzle with: - AnswerThe manufacturers recommended nozzle spray pattern and spray angle. Viscosity problems can be corrected by: - AnswerDecreasing the nozzle size and increasing the pump pressure accordingly The minimum operating pressure of an oil pump is: - Answer100 PSI If a stack relay fails you, must? - AnswerReplace it with an approved type controller Aquastats are normally found on what type of heating systems? - AnswerHydronic Airstats are found on what type of heating systems? - AnswerForced warm air systems Under sized returns on a warm air system can result in what? - AnswerShort cycling of the oil burner Incorrect nozzle selection in regards to gallon per hour, can result in what problems in a steam system? - AnswerSome radiators not heating quickly enough Low boiler water temperature in a hydronic hot water system may be caused by? - AnswerUndersized oil burner nozzles Delayed opening oil valves are used to

Meer zien Lees minder
Instelling
Massachusetts Oil Burner
Vak
Massachusetts Oil burner








Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Massachusetts Oil burner
Vak
Massachusetts Oil burner

Documentinformatie

Geüpload op
10 maart 2025
Aantal pagina's
4
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

©FYNDLAY 2024/2025 ALL RIGHTS RESERVED 8:10PM.




Massachusetts Oil burner Practice Exam
Questions And Answers 2025 Update.


The cross connection between two supply tanks shall not exceed? - Answer✔660 gallons

When is an automatic draft control not required? - Answer✔When the equipment is designed
to control the draft.

Combustion performance testing can indicate: - Answer✔Improper air oil mixture, too much
combustion air, and low pump pressure.
If a second oil-burning appliance is installed in a single chimney, you must insure: -
Answer✔Sufficient draft is available for safe operation of all connected equipment.

Delayed ignition can be caused by: - Answer✔Weak ignition transformer

You should replace the oil burner nozzle with: - Answer✔The manufacturers recommended
nozzle spray pattern and spray angle.

Viscosity problems can be corrected by: - Answer✔Decreasing the nozzle size and increasing
the pump pressure accordingly

The minimum operating pressure of an oil pump is: - Answer✔100 PSI

If a stack relay fails you, must? - Answer✔Replace it with an approved type controller

Aquastats are normally found on what type of heating systems? - Answer✔Hydronic

Airstats are found on what type of heating systems? - Answer✔Forced warm air systems

Under sized returns on a warm air system can result in what? - Answer✔Short cycling of the oil
burner
Incorrect nozzle selection in regards to gallon per hour, can result in what problems in a steam
system? - Answer✔Some radiators not heating quickly enough
Low boiler water temperature in a hydronic hot water system may be caused by? -
Answer✔Undersized oil burner nozzles

Delayed opening oil valves are used to? - Answer✔Allow oil pump to come up to speed

1

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Fyndlay Kaplan University
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
358
Lid sinds
1 jaar
Aantal volgers
80
Documenten
18668
Laatst verkocht
6 dagen geleden
Scholar\'s Sanctuary.

Explore a Vast Collection of Finely Made Learning Materials.

3.7

68 beoordelingen

5
32
4
8
3
13
2
6
1
9

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen