ASQ Calibration Technician Certification
Practice Exam-Graded A

The SI unit of length is the - correct Answer-Meter

The Pascal, the SI unit of pressure, is - correct Answer-A derived SI unit

Which SI multipliers have abbreviations in capital letters? - correct Answer-Those with
factors > 1000

The speed of light is considered to be a constant - correct Answer-When used for
standards work

The melting point of Gallium is a fixed point in the ITS-90 temperature system. The
uncertainty of the value of this temperature is - correct Answer-Zero

A certificate for a traceable calibration must show evidence to support - correct Answer-
The existence of a traceability path is needed for an audit

The realization of a temperature fixed point is - correct Answer-A physical object such
as a freezing point cell

Traceability is required when operating under ISO 9001 and related standards - correct
Answer-At every step of the calibration pyramid below national measurement standards

The ACME company's calibration procedure for their model VU-1 sound level meter
calls for the exclusive use of ACME sound level calibrator model SLC-1. A technician
has a rush job to calibrate a VU-1, but the SLC-1 is back at the factory in Europe for
repair and calibration. He/she should - correct Answer-Stop work and notify the
customer that the calibration cannot be completed until the proper IM&TE is available

In order to calibrate a digital ammeter, it is necessary to have - correct Answer-A source
or generator of current

The base SI unit for electrical quantities is - correct Answer-Ampere

One gram of oxygen gas is released into a box 10 cm on a side. What is the SI density
of the gas inside the box when equilibrium is reached? - correct Answer-1.0 kg/m^3

One million nanofarads is the same as - correct Answer-One millifarad

,Scales and balances should be calibrated after they are moved because - correct
Answer-Gravity is different in different places and internal mechanisms may have been
affected

A triple point of water cell is - correct Answer-A device for sourcing temperature

Substitution of standards - correct Answer-May be done if technically feasible and not
forbidden by procedure

Which of the following measuring systems is a resistance-temperature device (RTD)? -
correct Answer-Thermistor

Having traceable reference standards and providing traceable calibrations for a
laboratory's customers is necessary when - correct Answer-These customers need to
provide traceability to their customers

An optical pyrometer measures temperature by determining - correct Answer-The color
of the light from a hot body

An intrinsic standard - correct Answer-Will realize the unit for which it is a reference
when operated properly

The largest single contributor to the uncertainty of dimensional measurements is -
correct Answer-Temperature

The SI unit for time is based on - correct Answer-An atomic vibration

Which of the following notations accepted for use with the SI is preferred for the volume
of a gallon of milk? - correct Answer-3.785 L (1 U.S. gallon)

Carl Sagan, on his television series, might have said "Thank you for spending these
billions and billions of nanoseconds with me." How long a time interval is 1800 billion
ns? Note - use the U.S. definition of billion, e.g. 10^9 - correct Answer-Half an hour

Gravitational corrections are always required for - correct Answer-Measurements in
which a weight opposes a spring force

Which of the following temperature measuring devices requires either an actual or a
simulated reference temperature? - correct Answer-Thermocouple

Crash dummies used to simulate the effects of adults and children during testing of car
and truck collisions are an example of a - correct Answer-Consensus standard

Electrical sensors used to measure temperature almost always require - correct
Answer-Linearization of the temperature - electrical relationship

, A substitute standard has replaced the usual reference standard and the term "limited
calibration" is used on the UUT. Which of the following explanations would NOT be
expected as an explanation of the limited calibration? - correct Answer-The substitute
was used for a limited time

The most common working standard for dimensional analysis is - correct Answer-The
gage block

Measurement of humidity can be accomplished - correct Answer-With a mirror whose
temperature can be controlled

A laboratory that uses an intrinsic standard may not simply use it without verification,
but must also - correct Answer-Participate in interlaboratory comparisons or proficiency
testing for that parameter

The relationship between the freezing point of water and the triple point of water at
standard atmospheric pressure is - correct Answer-The triple point is warmer

The SI unit used by torque wrenches is - correct Answer-N*m

What ratio of attenuator would be required to reduce a 1.0 mW signal to a 1.0 fW
signal? - correct Answer-1 000 000 000 000 :1

The best reason that the local acceleration of gravity, little g, needs to be known by a
laboratory is because - correct Answer-It can affect many calibration results

When using saturated salt solutions to generate (source) humidity, it is important to
know the - correct Answer-Temperate

A client has submitted a 0 - 250 ft-lb, +- 5% of full scale, torque wrench to a lab for
calibration in the clockwise direction. The lab's 0 - 600 ft-lb, 0.25% of reading, clockwise
and counter-clockwise, electronic calibrator is out of order. The lab also owns a spring-
and-needle torque clockwise calibrator that is working and is in calibration. However, it
is 0 - 1000 ft-lb, 1% of reading 2 ft-lb. Can this calibrator be used instead? - correct
Answer-Yes, it is adequate for this job

Which of the following parameters can be converted to relative humidity using a table or
calculation? - correct Answer-Dew point

ANSI/NCSL Z540.3 requires that calibration procedures shall contain generic
descriptions of the IM&TE and reference standards to be used so that - correct Answer-
The technician has all the required information to make a substitution decision

A certificate of calibration issued by an NMI - correct Answer-May be considered
traceable without further evidence

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ALVINK2022 University of Oxford
View profile
Follow You need to be logged in order to follow users or courses
Sold
242
Member since
3 year
Number of followers
157
Documents
9475
Last sold
1 week ago

4.2

81 reviews

5
49
4
17
3
7
2
2
1
6

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions