MCC-NH GAS FITTERS EXAM
QUESTIONS WITH CORRECT ANSWERS
What do 2nd stage regulators compensate for? - Answer-Changes in downstream
demand

What can cast iron be used for? - Answer-Nothing

What Can't cast iron be used for? - Answer-Everything

What is Industry best practice pressure drop we design piping systems for - Answer-0.5"
w.c

Do regulators need to be readily accessible? - Answer-Yes

Do meters need to be readily accessible? - Answer-Yes

Do shutoffs need to be readily accessible? - Answer-Yes

A gas piping installation covered by NFPA 54 includes all fixed piping from where to
where? - Answer-LP- 1st stage regulator
Nat- Outlet of meter set

What table will be used to determine approximate inputs for typical gas appliance? -
Answer-Annex A Table 5.4.2.1 (A.5.4.2.1)

Gas meters shall be located in ventilated spaces readily accessible for what purposes?
- Answer-Examination / Reading / Replacement / Necessary Maintenance

Who shall we contact to obtain the heating value of the gas used? - Answer-The
Serving Gas Supplier

What CPN covers metallic piping joints and fittings? - Answer-5.6.7

What CPN covers plastic piping joints and fittings? - Answer-5.6.8

Line gas pressure regulators shall be listed in accordance with? - Answer-5.8..2.2

Please explain the two ways we accomplish venting a line gas pressure regulator. -
Answer-Piping a vent at or the installation a vent limiter

What will be required when the available supply pressure is higher than what the
appliance is designed for? - Answer-A Line Pressure Regulator

, Normal ASP for LP gas is? - Answer-11"w.c. to 14" w.c.

1 cubic foot of LP gas approximately contains how many BTU's? - Answer-2,500 BTU
(2.5 mBTU)

Metallic pipe threads shall be what? - Answer-Cut to specific lengths and sized using
the charts

Normal manifold pressure for LP gas is? - Answer-10"w.c.

Normal manifold pressure for natural gas is? - Answer-3.5"w.c.

The maximum design operating pressure for piping located inside a building shall not
exceed? - Answer-5 PSIg

The maximum design operating pressure for any gas piping system shall not exceed? -
Answer-125 PSIg

According to NFPA54 Gas piping systems shall be sized and installed to satisfy
maximum demand of the system while ensuring what? - Answer-Each appliance
receives not less than the minimum manifold pressure it requires

Normal ASP for Natural gas is? - Answer-3.5"w.c. to 8"w.c.

Please convert the following appliance input into the most appropriate unit of
measurement for the use with the charts pertaining to natural gas. 150,000 BTU/Hr. -
Answer-150, = 60cuft

1 cubic foot of Natural gas approximately contains how many BTU's? - Answer-1,000
BTU

What shall be requirement to be included on a piping plan? - Answer-Location ,
Sections , Segments, Outlets, Legend, Available Supply Pressure.

Who determines where the point of delivery will be? - Answer-The Serving Gas Supplier

What type of Plastic piping shall be used as gas pipe? - Answer-Polyethylene Pipe or
Polyamide

Can PVC be used as plastic piping? What is PVC commonly used for? - Answer-No
however it is commonly used for vent piping on gas regulators.

What is the purpose of an excess flow valve? - Answer-Stop the flow of gas when flow
exceeds the rating of the valve (such as a major pipe rupture)

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
biggdreamer Havard School
View profile
Follow You need to be logged in order to follow users or courses
Sold
247
Member since
2 year
Number of followers
68
Documents
17956
Last sold
12 hours ago

4.0

38 reviews

5
22
4
4
3
6
2
2
1
4

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions