Gxmo Ohio review Questions and Answers 100% Pass Contrast - The difference between any two adjacent portions of the image Attenuation - Absorption of the X-ray beam by matter Scatter radiation - Part of the X-ray beam that scatters in opposite direction, from the patient. Has less energy than primary beam. Not easily controlled Detent - Special mechanism that stops the X-ray tube in a specific location. Trendelenburgs position - Flat on back with head lower 15 degrees Grid - Device that absorbs most of the scatter radiation coming off pt, preventing it from reaching IR. Increases pt exposure. Floating tabletop - Allows the top of X-ray table to move independently, which makes it easier to align body part Bucky - Grid and pull out tray to hold the IR plate and center it to Central ray Stationary grid - Grid that does not move during exposure 2100% Pass Guarantee Sophia Bennett, All Rights Reserved © 2025 When to use a grid? - 10-12 cm or more in thickness or when kVp greater than 60 Upright cassette holder *UPRIGHT BUCKY* - Hold IR in upright position. Mounted on wall and able to be adjusted for height at 40 or 72 SID Control console *panel* - Where the limited operator sets exposure factors and Initiates the exposure Transformer cabinet - Used to produce high voltage required for X-ray production Fundamental rad safety - The potential hazard is greater for the limited operator than the pt because the limited operator is in frequent d

Montrer plus Lire moins
Établissement
Gxmo
Cours
Gxmo









Oups ! Impossible de charger votre document. Réessayez ou contactez le support.

École, étude et sujet

Établissement
Gxmo
Cours
Gxmo

Infos sur le Document

Publié le
24 février 2025
Nombre de pages
6
Écrit en
2024/2025
Type
Examen
Contient
Questions et réponses

Sujets

Aperçu du contenu

Gxmo Ohio review Questions and
Answers 100% Pass


Contrast - ✔✔The difference between any two adjacent portions of the image


Attenuation - ✔✔Absorption of the X-ray beam by matter


Scatter radiation - ✔✔Part of the X-ray beam that scatters in opposite direction, from the

patient. Has less energy than primary beam. Not easily controlled


Detent - ✔✔Special mechanism that stops the X-ray tube in a specific location.


Trendelenburgs position - ✔✔Flat on back with head lower 15 degrees


Grid - ✔✔Device that absorbs most of the scatter radiation coming off pt, preventing it

from reaching IR. Increases pt exposure.


Floating tabletop - ✔✔Allows the top of X-ray table to move independently, which

makes it easier to align body part


Bucky - ✔✔Grid and pull out tray to hold the IR plate and center it to Central ray


Stationary grid - ✔✔Grid that does not move during exposure




100% Pass Guarantee Sophia Bennett, All Rights Reserved © 2025 1

, When to use a grid? - ✔✔10-12 cm or more in thickness or when kVp greater than 60


Upright cassette holder *UPRIGHT BUCKY* - ✔✔Hold IR in upright position. Mounted

on wall and able to be adjusted for height at 40 or 72 SID


Control console *panel* - ✔✔Where the limited operator sets exposure factors and

Initiates the exposure


Transformer cabinet - ✔✔Used to produce high voltage required for X-ray production


Fundamental rad safety - ✔✔The potential hazard is greater for the limited operator

than the pt because the limited operator is in frequent daily contact


Sources of radiation - ✔✔X-ray tube and any matter that is in the path of the X-ray

beam


Principle source of scatter? - ✔✔The patient


Should the limited be involved in holding patients? - ✔✔No never. Immobilization

devices or the patients family if need be


What should the GXMO do before making an exposure? - ✔✔Perform a safety check.

Make sure the X-ray door is closed. No one in X-ray room. Your completely behind

Barrier. No other IRs in the exposure area.


The source of X-rays? - ✔✔In a very small area inside the X-ray tube.




100% Pass Guarantee Sophia Bennett, All Rights Reserved © 2025 2

Faites connaissance avec le vendeur

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
SophiaBennett Howard Community College
Voir profil
S'abonner Vous devez être connecté afin de suivre les étudiants ou les cours
Vendu
131
Membre depuis
1 année
Nombre de followers
5
Documents
9104
Dernière vente
4 jours de cela
EXAM GAME-CHANGER

Exam Questions and Answers Section : Study Like a Pro, Study Smart, Study with Sophia.

3.7

26 revues

5
10
4
5
3
7
2
1
1
3

Récemment consulté par vous

Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Foire aux questions