Identify two correct statement about conducting a daily inspection of a MWS apparatus equipped with a
fire pump - Answers Confirm that the foam tank level is full Operate the pump drive control
The purpose of the priming device test is to - Answers Evaluate how quickly the priming device can
create a vacuum to bring water through a pump to the discharge hose
During a pre-service hydrostatic test, each pump is hydrostatically tested at a minimum of - Answers 500
psi over the pump designed maximum operating pressure for 10 minutes
Identify two items that should be included on the daily MWS apparatus records - Answers Coolant levels
tire condition
The total stopping distance is - Answers The sum of the driver operator reaction distance and the MWS
apparatuses braking distance
When driving through intersections requiring a stop, you must perform all of the following steps except -
Answers Turn on the flashers to indicate you are crossing
Identify the four steps for passing through a straight section of a road or highway - Answers Check for
oncoming traffic
check the side and rear view mirrors maintain apparatus speed
check the side street or roads
You should never back and MWS Apparatus - Answers If you don't have at least one spotter
Since salt water or water containing certain chemicals can corrode the apparatus pump, you should -
Answers Flush the pump with fresh water after using it
The best type of strainer to use in a shallow stream is a - Answers Floating strainer
Match each type of pressure with its correct description - Answers Head pressure - pressure caused by
the height of a water supply above the discharge point
Static pressure - available pressure at a discharge point without water flowing
Flow pressure - The forward velocity of water at the discharge point
Residual pressure - water pressure in a distribution system that is still available when a hydrant is
flowing
Normal operating pressure - water pressure in a distribution system during regular consumption
The best definition of water pressure is the - Answers Force of water per unit area
, When hose diameter remains the same, friction loss varies approximately with the square of the
increase in flow rate therefore, if gallons per minute triples - Answers Friction loss is nine times greater
Large diameter hoses are generally defined as holes with a diameter between - Answers 4 and 6 inches
One characteristic of discharge pressure relief valves is they - Answers Are slow to close after being
opened
According to NFPA 1901, a discharge pressure relief valve must operate within - Answers 10 seconds
after discharge pressure rises 30 psi above the set level
When controlling pump valves, push-pull handles - Answers Can accurately control line pressure and be
locked into place.
Place the step for pumping from an MWS apparatus internal tank to an attack apparatus or a nurse
tanker once the MWS apparatus has been positioned in the correct order - Answers Deploy and connect
the supply line
make the pump operational
open the tank to pump valve
prime the pump, if necessary
open the discharge valve slowly
Set the throttle to the required engine pressure
set the pressure relief valve or the governor
monitor gauges associated with pump operation and make decisions based on your departments SOP's
and experience
Fill site pumpers should have a minimum pump capacity of - Answers 1000 GPM
The best fill and dump sites are those in which - Answers The MWS apparatus driver operator can drive
straight in from one direction, fill or dump, and then proceed straight out the other end at both sites
As operations proceed during water shuttles, make and break personnel at the fill site should monitor -
Answers Ground conditions
At a fill site, a cone or similar device is used to - Answers Mark the stopping point for an MWS apparatus
The most efficient water shuttle dump site locations contain the water using - Answers Portable water
tanks
The basic goal of a multiple portable water tank operation is to keep - Answers The tank being drafted
from full at all times