PLUMBING REVISED MOCK EXAM 2025/2026 QUESTIONS WITH 100% CORRECT ANSWERS The most accurate indicator of local rainfall is the - 100-year average The ability of soil to absorb water is called - Permeability Siphonic roof drain system are engineered drainage system that operate by - Suction Plumbers usually installer horizontal branches with 1/8 slope in 12 inches of pipe is equal - A 1 percent slope A 8 inch pipe diameter how many DFUs in 1/8 slope per food - 1,600 When a DFUs value has not been determined use the standard value of - 7.5 gpm The same amount of rainfall is equal in volume - 1.25 gallons A 6-inch horizontal pipe in 1/8 ,1/4 and 1/2 unit vertical slope rainfall are - In 1/8 - 10,700 1/4- 15,100 1/2- 21-400 To prevent frost buildup in the vent pipe enlarge the section of pipe that extends above the roof - Cause by water in the ven air condensing and buildup in the inside of the vent pipe and come in contact with could outside air

Show more Read less
Institution
Plumbing
Course
Plumbing











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Plumbing
Course
Plumbing

Document information

Uploaded on
February 13, 2025
Number of pages
31
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

PLUMBING STUDY GUIDE EXAM 2025/2026 QUESTIONS
WITH 100% CORRECT ANSWERS
Building sewers shall be tested by completely filling the sewer with water from the ______

A. Lowest to highest point

B. Lowest to at least 5' head

C. Lowest to at least 10' head

D. Lowest to at least ground level - C. Lowest to at least 10' head



Hot and cold-water piping may be tested with ____

A. 40 psi-150 psi water for 10 minutes

B. 35 psi for at least 15 minutes

C. 50 psi or the working pressure of the water in the system for at least 15 minutes

D. 100 psi of air for at least 10 minutes - C. 50 psi or the working pressure of the water in the system
for at least 15 minutes



The required clearance in front of a 3" cleanout is ____

A. 12"

B. 18"

C. 24"

D. 36" - B. 18"



A stack as defined in the code is ____

A. Main vent

B. Any vertical vent

C. The vertical main of a soil, waste, or vent piping which extends one or stories

D. Horizontal main of a soil, waste, or vent stack - C. The vertical main of a soil, waste, or vent piping
which extends one or stories



Above ground PEX piping installed horizontally shall be supported at intervals not to exceed
_________.

A. Depends on the pipe size

B. 24"

,C. 32"

D. 36" - C. 32"



The minimum vertical length for a gravity type venting system serving a fuel fired water hear is
_________.

A. 4'

B. 5'

C. 10'

D. Based on the Btu rating - B. 5'



The maximum horizontal distance of a trap arm is measure from the inner edge of the vent to the
_____

A. Weir of the trap

B. Dip of the rap

C. Inlet of the trap

D. None of the above - A. Weir of the trap



Sleeves shall be provided to protect piping ____

A. Passing through floors or concrete walls

B. Passing through concrete and masonry walls

C. Passing through wood or concrete walls

D. Passing through all locations listed above - B. Passing through concrete and masonry walls



The drain connecting the compartments of a set of fixtures to its trap is called a/an _____

A. Continuous waste

B. Combination waste and vent

C. Indirect waste

D. None of the above - A. Continuous waste



A device to prevent backflow in to the potable water system is called a _____

A. Backflow connection

B. Backflow preventer

,C. Backwater preventer

D. Both A and B - B. Backflow preventer



Copper tube and fittings used for drainage and vent piping installed above ground shall be at least
________

A. Type L

B. Type M

C. Type K

D. Type DWV - D. Type DWV



All trenches deeper than the footing of any building or structure and paralleling the same must be at
least _____

A. 45 degrees therefrom

B. 4' therefrom

C. 2' therefrom

D. 90 degrees thereform - A. 45 degree therefrom



The minimum size trap and trap arm for a kitchen sink is _______

A. 1.5 inches

B. 2 inches

C. 1 1/4 inches

D. Either A or B - A. 1.5 inches



Horizontal drainage liens connecting with other horizontal drainage lines shall enter through
__________

A. 45 degrees wye branches

B. Sanitary tee branches

C. 1/4 bend with end outlet

D. Side inlet sweep - A. 45 degrees wye branches



For each run of horizontal drain piping, the distance between cleanouts shall not exceed ____

A. 50'

, B. 75'

C. 100'

D. None of the above - C. 100'



A plumbing vent shall terminate no less than ____

A. 3' from an air intake

B. 10' from an air intake

C. 1' above the roof

D. 3' above a parapet wall - B. 10' from an air intake



Each drainage stack which extends 10 or more stores above the building drain shall be served by
_____

A. Cleanouts

B. A parallel vent stack

C. A parallel stack vent

D. Straps every 10 feet - B. A parallel vent stack



Chemical or industrial liquid wastes which are likely to damage th public sanitary sewer system shall
_______

A. Be drained into a holding tank

B. Not be used under any conditions

C. Pretreated to render them innocuous

D. Be drained into a storm drain - C. Pretreated to render them innocuous



Special venting for island fixtures is used for ______

A. Bathtubs

B. Showers

C. Kitchen sinks

D. Washing machines - C. Kitchen sinks



The vertical distance between a fixture outlet and the trap weir shall not exceed ____

A. 12"
$9.99
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
ScoreSphere
4.0
(1)

Get to know the seller

Seller avatar
ScoreSphere john
View profile
Follow You need to be logged in order to follow users or courses
Sold
1
Member since
10 months
Number of followers
0
Documents
861
Last sold
7 months ago
SCORE SPHERE

On this page, you will find all available study materials, including comprehensive documents and exclusive package deals provided by ScoreSphere. These resources cover a wide range of subjects and are designed to help students grasp complex topics efficiently

4.0

1 reviews

5
0
4
1
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions