A systems engineer sizers an environment based on the customer's
requirement of N+2 resiliency for the entire cluster. In which two ways
could the configuration be changed to meet the customer's requirements ?
(Choose Two)
Increase the RAM capacity per Node Increase the SSD capacity per Node
A prospective customer indicates a requirement to replicate data offsite for
a production workload. Which two questions should the systems engineer
ask (Choose Two)
What are the retention requirements?How much data needs to be replicated?
Which two collection tool outputs can be imported into Nutanix Sizer
(Choose two)
Collector RVTools
What is the main function of Oplog?
-A persistent write buffer to coalesce bursts of random writes before
destaging to the extend store
When Discussing node failures. a customer raises the concern that if a
node that host 100TB of data goes offline. building data must take an
extended period of time
Distribution of rebuild tasks across all nodes
A systems engineer needs to size a new project that requires offsite
backup using Veeam. The prospect requires an RPO of 24 hours, and the
ability to restore from the past 7 days of backups. The prospect's data
change rate is 1%. How should the SE configure the SE configure Sizer for
this scenario?
Yes Mine Veeam
, An existing customer wants to upgrade their non-AHV hypervisor to the
most recent version. The customer needs confirm that the hypervisor is
supported on their AOS version. Where on the Support Portal is this
information located?
Compatibility Matrix
A customer needs to increase availability in their Nutanix environment by
enabling rack awareness. The current configuration consists of : 1 RF2
cluster consisting of 7 identical NX-3170 1U nodes , All Storage
efficiencies are disabled , Which two changes should the systems engineer
propose to meet the customer requirements ? (Choose two)
Add 2 additional NX-3170 1U nodes. Distribute nodes across 3 separate
racks.
Based on their current workload. a customer request the systems engineer
to create a solution that does not exceed 80% CPU utilization when a node
is placed in maintenance mode (N+0) When creating the Sizer Scenario in
Automatic Mode, how can the systems engineer accomplish this?
-Customize the CPU threshold in the scenario's sizing options.
A prospective customer's migration to their new SAN started six months
ago and is sill not complete. The VP of IT state the previous migration to
the existing SAN took almost eight months to complete. How should the
systems engineer describe Nutanix hardware refreshes to this prospective
customer
-New nodes can be added to an existing cluster. and then the old nodes can
be removed.
A customer previously purchased a Nutanix solution of nine NX-3060-G7
nodes. The customer asks for help to increase the resiliency of their
environment after power outages to individual racks in their datacenter
Their current solution consists of two NX-3460-G7 blocks and a single NX-
3160-G7 block placed in a single rack. what should the systems engineer
recommend to this customer ?