AMMUNITION AND EXPLOSIVES STORAGE
SAFETY (CERT) (AMMO 112) Exam Questions
And Answers| Already Graded A+| Latest
Update.
Which hazard class/division would cause mass fragmentation if initiated? - Answer✔HD 1.1
You need to know storage compatibility of an explosive item before you store it. Which official
regulation can you use as a reference for storage mixing? - Answer✔DA PAM 385-64
You have closed and sealed a magazine that will no longer be used. how often are you required
to check the seal? - Answer✔Every 12 months
You are planning the necessary firebreaks for a new ECM. You must have a 5-foot firebreak
around the - Answer✔vents.
You oversee a magazine with an integral lightning protection system (LPS). To ensure the LPS
works, a certified professional must conduct an electrical test survey every - Answer✔24
months
What type of lighting protection system (LPS) does this building have? - Answer✔Mast
You arrive at a magazine and find a truck parked just outside the magazine. Which statement
applies? - Answer✔Vehicles must be parked at least 50 feet away from a magazine.
Of the operations listed below, which operation is ALWAYS ALLOWED inside a magazine
containing ammunition? - Answer✔Taking inventory
You are painting this week. If the explosives operating facility has a fire extinguisher and a
grounded storage cabinet designed for flammable materials, you are allowed to store enough
paint inside the explosive operating facility for - Answer✔One day of work.