100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

Master Electrician Exam Review Questions and Answers Latest Updated 2025 Graded A+

Rating
-
Sold
-
Pages
23
Grade
A+
Uploaded on
07-02-2025
Written in
2024/2025

That portion of a wiring system extending beyond the final overcurrent device is called the: - branch circuit The final sum of the computed loads, based on the minimum code requirements, is the - Calculated load As compared to #10, a #8 wire of the same Iength has less: - Resistance One circular mil is the area of a circle whose diameter is: - 0.001 inch A round bus-bar one inch in diameter, has a circular mil area of: - 1,000,000 cm A copper wire with twice the diameter of another wire has a current carrying capacity: - four times as great The specific resistance of copper wire @ 20° C in ohms per circular mil ft. is - 10.4 Conductance of an electric circuit is that property that will: - permit current to flow The equivalent value of 0.1 mho is - 1O ohms The resistance of copper wire is: - directly proportional to its length The portion of a wiring system between a point of distribution and the branch circuit overcurrent device is - Feeder GFCI protection at a carnival is not required for equipment at circuit if the receptacle is of the ____________type - locking Where cables or nonmetallic raceways are installed through in joists, rafters, or wood members;holes shall be bored so that the edge of the hole is the nearest edge -of the wood member. - not less than 1 1/4 in. from To guard live parts over 50V but less than 600V, equipment is permitted to be - located on a balcony accessible only to qualified persons located in a room only accessible to qualified persons elevated 8 ft or more above floor or other working surface Overhead feeder conductors shall have a minimum __________ vertical clearance over residential property and driveways, as well as those commercial areas not subject to truck traffic, where the voltage is limited to 300 volts-to-ground. - 12Ft Where rear access is required to work on de-energized parts on the back of enclosed equipment, a minimum working space of horizontally shall be provided. - 36 inches What is the maximum run length of a 18AWG fixture wire that is tapped on to a 20 amp branch circuit? - 50' When the service disconnecting means is a power-operated switch or circuit breaker, it shall be able to be opened by hand in the event of a - power supply failure Conductors are considered outside a buildings when they are buried under not less than - 2 in of concrete In straight pull, the length of the box shall not be less than. ____times the trade size of the largest raceway. - 8 At least one receptacle outlet shall be installed within of the top of a show window for each 12 linear feet measured horizontally across its length - 18" Ground-fault protection of equipment shall be provided fro solidly grounded wye electrical services of more than 150 volts-to-ground, but not exceeding 600V phase-to..phase for each service disconnecting means rated - 1000A Receptacle outlets in floors shall not be counted as part of the required number of receptacle outlets unless located within ______ of the wall - 18" Exposed live parts of motors and controllers operating at or more between terminals shall be guarded against accidental contact by enclosure or by location - 50V Lighting track shall not be installed less than______ above the finished floor except' where protected from physical damage or where the track operates at less than 30 V rms, open-circuit voltage - 5' Each general care area patient bed location shall be provided with a minimum of_______receptacles, which can be single, duplex, or a combination with each duplex counting as two receptacles - 4 In a Dwelling Unit which appliance is allowed to have a 24" cord with attachment ground plug? - Combination Range hood/ Microwave oven At least_____ 125 V, single phase, 15 A or 20 A, duplex with groundfault circuit interrupter receptacle shall be provided in each elevator machine room and elevator machinery space. - 1 Lighting systems covered by Article 411 shall have a power supply rated not more than______and not more than 30V - 25A Temporary electrical power and lighting installations shall be permitted for a period not exceeding ____days for Christmas decorative lighting and similar purposes - 90 Lighting systems operating at 30V or less shall not be·installed within_______of pools, spas, fountains, or similar locatipns - 10' Where communications wires and cables and electric light or power conductors are supported by the same pole and are run paralled to each other in span , the·supply service drops of 0-750 volts running above and parallel to communications service drops shall have a minimum separation of _______inches at any point in the span, including the point of and at their attachment to the building, provided the nongrounded conductors are insulated and that a clearance of not less than_______ inches is maintained between the two services at the pole - 12 /40 Communications Wires and cables shall have a vertical clearance of not less the ______feet from all points of roofs above which they pass. - 8 MV cable rated 35 KV cannot be installed in - Cable Tray The grounding of communications wires should be run to the grounding electrode: - in a straight line Service Lateral conductors that supply power to limited loads of a single branch circuit-such as a small polyphase power, controlled water heaters, and similar loads-shall not be smaller than - 10 AWG Copper Dry type transformers installed indoors rated over._______ shall be installed in a vault. - 35KV Flat:top underfloor raceways over 4 inches, but less 8 inches wide, with a minimum 1 inch spacing between raceways, shall be covered with concrete to a depth of not iess than 1 inch. Raceways spaced less that 1 inch apart shall be covered with a concrete to a depth of - 1 1/2" For straight pulls, the length of a pull box shall not be less than _____ time the outside diameter, over the sheath, of the largest shielded ·or lead covered conductor or cable entering the box on systems over 600 volts - 48 times For switchboards that are not totally enclosed, a space of ____ or more shall be provided between toe top of the switchboard and any combustible ceiling - 36" A disconnecting means that serves a hermetic refrigerant motor compressor shall have an ampere rating of at least percent of the nameplate rated load current or branch circuit selection current, whichever is greater. - 115% Class 2 and class 3 cables listed as suitable for general purpose use with the exception of risers, ducts, plenums, and other spaces used for environmental air, shall be Type ______ - CL2 and CL3 Branch circuit conductors within _____of a ballast shall have an insulation temperature rating not lower than 90 degree Cor 194 degree F - 3 inches Communications circuits shall have a minimum grounding conductor of _____AWG - 12 AWG A separation of at least ______shall be maintained between communications wires and cables on buildings and lightning conductors, where practicable - 6 feet When mounting a light fixture supported be EMT over a hot tub protected by GFCI must have a height of - Not Allowed in NYC How many # 10 conductors can be legally installed in a 4 inch square box, 2 1/8 deep? - 12

Show more Read less
Institution
NCCER
Course
NCCER










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
NCCER
Course
NCCER

Document information

Uploaded on
February 7, 2025
Number of pages
23
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
shadow251 NURSING
View profile
Follow You need to be logged in order to follow users or courses
Sold
261
Member since
3 year
Number of followers
30
Documents
4754
Last sold
3 days ago

4.1

56 reviews

5
36
4
6
3
4
2
2
1
8

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions