CPO Practice EXAM QUESTIONS & ANSWERS 2025 (Already Graded with 100% Pass rate)
CPO Practice EXAM QUESTIONS & ANSWERS 2025 (Already Graded with 100% Pass rate) Which type of filter requires the least amount of water to clean? (A) Diatomaceous (B) Rapid rate sand (C) High rate sand (D) Cartridge (D) Cartridge Cyanuric acid (stabilizer) protects free chlorine (FC) against the effects of: (A) Pathogens like Crypto, Giardia, and Shigella (B) High Total dissolved solids (C) Ultraviolet rays from the sun (D) High PH (C) Ultraviolet rays from the sun An erosion chemical feeder is what type of feeder? (A) Peristaltic pump (B) Piston pump (C) Dry chemical feeder (D) Gas system (C) Dry chemical feeder OSHA requires aquatic facilities to maintain: (A) Safety Data Sheets only for sanitizing chemicals (B) Lifeguard certifications (C) Air temperature recordings (D) SDS's for all chemicals used at the facility (D) SDS's for all chemicals used at the facility When mechanical cooling is used on an indoor therapeutic pool facility, the recommended ASHRAE fresh air exchange rate should be: (A) 2 to 4 exchanges per hour (B) 4 to 6 exchanges per hour (C) 6 to 8 exchanges per hour (D) As many as possible (B) 4 to 6 exchanges per hour What condition mandates an immediate closure of your swimming pool? (A) Locker room is not clean (B) Main drain not visible from the deck (C) No automatic feeders installed (D) No underwater lights installed (B) Main drain not visible from the deck The reagent commonly used to test PH is: (A) DPD (B) Sodium Thiosulfate (C) Coolomatic (D) Phenol red (D) Phenol red When should you backwash high rate sand filters that have a single pressure gauge? (A) After an 8 to 10 psi increase above starting pressure (B) Every 2 days (C) Once per week (D) When the influent and effluent gauges are 10 to 20 psi apart (A) After an 8 to 10 psi increase above starting pressure Oxidation Reduction Potential testing (ORP) is measured in: (A) Parts per million (ppm) (B) Millivolts (mV) (C) Gallons per minute (gpm) (D) Free available chlorine (FAC) (B) Millivolts (mV) How much sodium thiosulfate would you need to lower the free chlorine from 18 ppm to 2.0 ppm in a 150,000 gallon pool?
Escuela, estudio y materia
- Institución
- CPO certified pool operator
- Grado
- CPO certified pool operator
Información del documento
- Subido en
- 29 de enero de 2025
- Número de páginas
- 22
- Escrito en
- 2024/2025
- Tipo
- Examen
- Contiene
- Preguntas y respuestas
Temas
- cpo practice exam
-
which type of filter requires the least amount of
-
cyanuric acid stabilizer protects free chlorine
-
an erosion chemical feeder is what type of feeder
Documento también disponible en un lote