X-ray locks in NOMAD Pro 2 automatically engage after 2 hours of inactivity. - False Because NOMAD Pro 2 shielding limits the exposure, it is permissible to have other people In the exam room during exposures without any precautions. - False The NOMAD Pro 2 should be routinely cleaned using disinfectant wipes, or some other non- acetone cleaner to maintain cleanliness. - True The backscatter shield is adjustable to accommodate positioning devices and other special needs but if the backscatter shield is adjusted, additional precautions are required. - True The smaller diameter cone of the NOMAD Pro 2, combined with the use of DC power, and primary shielding greatly reduce a patient X-ray exposure. - True When the NOMAD Pro 2 is powered on and in the settings screen, a single quick pull of the trigger will enable the device. The green LED will illuminate and the display will indicate the device is ENABLING X-RAYS and then the ________________ message will appear on the screen (meaning the next trigger will fire X-rays). - READY / Green Radiation Icon When the NOMAD Pro 2 is not in service, it is advisable to ensure that the device is securely stored and the X-rays are ______ so that unauthorized / unintended use or damage does not occur. - LOCKED

Show more Read less
Institution
Course

Content preview

Nomad pro 2


Nomad pro 2 exam
Based questions and approved answers

X-ray locks in NOMAD Pro 2 automatically engage after 2 hours of inactivity. -
✔✔✔False


Because NOMAD Pro 2 shielding limits the exposure, it is permissible to have other people
In the exam room during exposures without any precautions. - ✔✔✔False


The NOMAD Pro 2 should be routinely cleaned using disinfectant wipes, or some other
non- acetone cleaner to maintain cleanliness. - ✔✔✔True


The backscatter shield is adjustable to accommodate positioning devices and other special
needs but if the backscatter shield is adjusted, additional precautions are required. -
✔✔✔True
The smaller diameter cone of the NOMAD Pro 2, combined with the use of DC power, and
primary shielding greatly reduce a patient X-ray exposure. - ✔✔✔True


When the NOMAD Pro 2 is powered on and in the settings screen, a single quick pull of the
trigger will enable the device. The green LED will illuminate and the display will indicate
the device is ENABLING X-RAYS and then the ________________ message will appear
on the screen (meaning the next trigger will fire X-rays). - ✔✔✔READY / Green Radiation
Icon


When the NOMAD Pro 2 is not in service, it is advisable to ensure that the device is
securely stored and the X-rays are ______ so that unauthorized / unintended use or damage
does not occur. - ✔✔✔LOCKED



@pg. 1

, Nomad pro 2
An alarm indicating a partial exposure (when the trigger was not depressed through the
entire timer setting, either on purpose or accidentally) is indicated by a series of beeps and
the ____________ message on the screen until a button is pressed. - ✔✔✔INCOMPETE /
RED


Do not ____ the NOMAD Pro 2 until the patient and film/ sensor are positioned and ready
to avoid unintended firing of the NOMAD Pro 2. - ✔✔✔ENABLE / READY


When there is not enough battery charge left to take an exposure, the charge indicator bars
will fade away and the ____ alarm message appears on the screen, and the NOMAD Pro 2
will not allow an exposure to begin. - ✔✔✔RECHARGE HANDSET


If left unused NOMAD Pro 2 will automatically shut down after approximately
______________ minute(s). The NOMAD Pro 2 can also be turned off by pressing the
POWER button. - ✔✔✔3 minutes


Some battery ____ may be lost during extended inactivity (leading to fewer exposures
between each Handset charging session). - ✔✔✔charge


In order to maintain the optimal operator safety zone the backscatter shield should be:
a) held so it is parallel to the oeprator
b) slid back on the cone toward the operator
c) held so NOMAD Pro 2 is positioned close to the patient - ✔✔✔a) Held so it is parallel to
the operator
c) Held so NOMAD Pro 2 is positioned close to the patient.


The duty cycle (or rest period b/w exposures) to protect your NOMAD Pro2 is as follows:
a) 6 sec for an exposure 0.09 sec long
b) 12 sec for an exposure 0.20 sec long


@pg. 2

Written for

Institution
Study
Course

Document information

Uploaded on
January 27, 2025
Number of pages
5
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$6.09
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
ProfessorJazz

Get to know the seller

Seller avatar
ProfessorJazz Harvard University
Follow You need to be logged in order to follow users or courses
Sold
1
Member since
3 year
Number of followers
0
Documents
92
Last sold
7 months ago

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions